Setting the Detection Surface Selection
Detection surface selection:
The default value is FIRST. Setting the value to MAX can decrease incorrect
measurements caused by diffused reflection or multireflection due to the shape of the
workpiece.
Procedure for setting up detection surface selection
1
Set to the MENU mode
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
MENU mode.
Press the button to display
.
* This step is not required if
detail menu display is
already set to ON in the
MENU mode.
Press the button to set the
display to
to set display of
the detail menu.
Press the
button to apply
the setting.
Sensor Head
NEAR
FAR
Measurement performed on
the NEAR side
(with the FIRST setting)
Measurement performed with
correct reflection components
(with the MAX setting)
Correct reflection
Correct
reflection
Multireflection
Multireflection
Measurement
while moving
Detection surface
selection setting
2
Return to RUN mode
3
Set to the MENU mode
1
Setting completed
Hold down for
3 seconds
Lit
Press to display
.
Press to display.
Setting channels used when connecting multiple units: Each CH