Error Messages
131
ZX2 User’s Manual
131
INTRODUCTION
BASIC
SETUP
PREPARATION
FOR
MEASUREMENT
TROUBLE-
SHOOTING
INDEX
CONTENTS
SETTING
TRANSITION
CHARTS
FLOW OF
OPERATION
MAIN
APPLICATIONS
& SETTING
METHODS
DETAILED
SETTINGS
SPECIFI-
CATIONS
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
Error-head
Sensor Head system error.
• Turn OFF the power supply, check
the Sensor Head connection, and
then turn ON the power supply
again.
• If the above countermeasure does
not solve the problem, the Sensor
Head is malfunctioning. Replace
the Sensor Head.
Error-head
Error-head
Error-head
Because the Sensor Head version is
old, the connected Amplifier Unit
cannot be used.
• Contact the company with which
your company is doing business or
the OMRON sales representative
handling your company.
Error-memory
Amplifier Unit setting memory error.
• Turn OFF the power supply, check
if wiring is connected correctly, and
then turn ON the power supply
again.
• If the above countermeasure does
not solve the problem, the
Amplifier Unit is malfunctioning.
Replace the Amplifier Unit.
Error-memory
Amplifier Unit setting memory error.
• Initialize the settings by holding
down the SET key for at least three
seconds.
• If the above countermeasure does
not solve the problem, the
Amplifier Unit is malfunctioning.
Replace the Amplifier Unit.
Error-short
One or all of the judgment outputs are
short-circuited.
• Turn OFF the power supply, check
that the HIGH, PASS, LOW or
error output lines are not short-
circuited, then turn ON the power
supply again.
Error-system
Amplifier Unit system error.
• Turn OFF the power supply, check
if wiring is connected correctly, and
then turn ON the power supply
again.
• If the above countermeasure does
not solve the problem, the
Amplifier Unit is malfunctioning.
Replace the Amplifier Unit.
Tuning-failed
Smart Tuning failed.
(The error output signal is not output.)
• Change the response time setting
to a larger value, and try again.
• Make sure that the distance
between the Sensor and
Workpiece is within the
measurement range, and try again.
Display
Error