For the timing at which these signals are input, see the timing charts on pages 144
to 146.
Red
Reset input/BANK
input 1 (switched
by external input
setting)
Reset input:
While a reset signal is being input,
is displayed
on the sub-display.
• When the hold function is not used
The output while a reset signal is being input is held in
accordance with the output during non-measurement
setting.
This feature can be used in cases such as to input a
mask signal if you want to stop output for a certain
period.
• When the hold function is used
If a reset signal is input, the state in effect before the
hold function was set will be restored.
(For details on the hold function, see page 93, and
for details on the output during non-measurement,
see page 111.)
BANK input 1:
Signal input wire for bank switching. Banks are switched
by ON/OFF combinations with BANK input 0.
When connecting two or more Amplifier Units, use the
CH1 Amplifier Unit for bank switching. The banks of the
Amplifier Units of CH2 and later are switched together
with CH1.
(For details on switching and inputs, see page 118.)
Cable
color
Name
Function