Connecting Two or More Amplifier Units
87
ZX2 User’s Manual
INTRODUCTION
BASIC
SETUP
PREPARATION
FOR
MEASUREMENT
TROUBLE-
SHOOTING
INDEX
CONTENTS
SETTING
TRANSITION
CHARTS
FLOW OF
OPERATION
MAIN
APPLICATIONS
& SETTING
METHODS
DETAILED
SETTINGS
SPECIFI-
CATIONS
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
The displayed and set up menus differ depending on the channel when two or more
Amplifier Units are connected and when mutual interference prevention is set to ON.
Use the Amplifier Units of the corresponding channel numbers to specify settings by
referring to the tables below.
<Menus and setting channels when two or more Amplifier Units are connected>
<Menus and setting channels when mutual interference prevention is set to ON>
(For details on the setup procedure when mutual interference prevention is set to
ON, see the next page.)
Menu
CHs Used to
Specify
Settings
CHs Not Used to Specify Settings
Notes
Mutual interference
prevention
CH1
CH2 to CH5: These cannot be used.
(The setting menu is not displayed on
the digital display.)
The setting of CH1 is also
applied to Amplifier Units of CH2
and later.
Two-sensor
operation setting
Thickness setting
CH2 to
CH5
CH1: This cannot be used.
(The setting menu is not displayed on
the digital display.)
Bank switching
setting
CH1
CH2 to CH5: These cannot be used.
(The setting menu is not displayed on
the digital display.)
• The Amplifier Units of CH2
and later are switched
together with CH1. (Bank
registration is possible for
individual amplifier units.)
• Also use CH1 to switch the
banks by means of an
external input.
Initialization
CH1
CH2 to CH5: These cannot be used.
(The setting menu is not displayed on
the digital display.)
The Amplifier Units of CH2 and
later are initialized together with
CH1.
Menu
CHs Used to
Specify
Settings
CHs Not Used to Specify Settings
Notes
Response time
setting
CH1
CH2 to CH5: These cannot be used.
(The setting menu is not displayed on
the digital display.)
The setting of CH1 is also
applied to Amplifier Units of CH2
and later.
Smart tuning
CH1
CH2 to CH5: Smart tuning cannot be
executed for these separately.
Smart tuning for the Amplifier
Units of CH2 and later are
executed together with CH1.