Zero Reset
Zero reset:
This refers to setting the reference value to "0" or any desired numeric value so that
the measured value can be displayed and output as a positive or negative deviation
(tolerance) from the reference value. The measured value can be set to "0" or any
desired numeric value at any timing in the RUN mode.
Examples:
To eliminate reference deviation
To measure steps in a sensing object
by a single sensor (Executing a zero
reset at each measurement)
To display the height of a workpiece
To display the actual measuring
distance value
1.5 0
3.5 2 (HIGH threshold)
-0.5 -2 (LOW threshold)
Sensing
object
Sensor Head
Measure
this step.
Zero reset is
executed.
Zero reset is
executed.
Zero reset is
executed.
(Note) Zero reset memory set to OFF
Sensor Head
Moved
0 3
2 5 (HIGH threshold)
-2 1 (LOW threshold)
Sensing
object
Sensor Head
0 50
2 52 (HIGH threshold)
-2 48 (LOW threshold)
Sensor Head
Sensing
object
Setting channels used when
connecting multiple units: Each CH