BASIC SETUP
40
ZX2 User’s Manual
INTRODUCTION
MAIN
APPLICATIONS
& SETTING
METHODS
SPECIFI-
CATIONS
INDEX
SETTING
TRANSITION
CHARTS
DETAILED
SETTINGS
FLOW OF
OPERATION
CONTENTS
PREPARATION
FOR
MEASUREMENT
BASIC
SETUP
TROUBLE-
SHOOTING
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
a
BASIC SETUP
Display of RUN Mode
Simplest Setting
Smart Tuning (Single Smart Tuning)
Smart tuning sets optimum sensing conditions according to the operating conditions
(response time and color/state of workpiece)
*
To tune multiple workpieces or to tune workpieces having a different surface
condition:
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
—
—
Set the reference workpiece in
place, adjust the position of the
Sensor Head while looking at the
digital display values on the
Amplifier Unit or the indicators on
the Sensor Head so that the
distance between the Sensor Head
and the workpiece is the
measurement center distance, and
install the Sensor Head at this
position.
Press the
button for one
second. When
/
is displayed, release
your finger from the button to
start execution of smart tuning.
If "
" flashes on the
sub-display for three
seconds, it indicates that
tuning was not possible.
Change the response time
setting to a larger value, and
try again.
HIGH threshold
LOW threshold
Analog output value
5 V, 1 to 5 V
40 to 20 mA
Current value
Resolution
*1 The main display always shows the measured value.
Default measured values are as follows:
0 reference: Measurement center distance,
+ indication: NEAR side
- indication: FAR side
* The numerals shown in the above diagram are an example only. The actual display may be different.
* For how to select the initial sub-display to be displayed when the power is turned on, see page 84.
Hold down for
1 second
Flashing
Pressing down
Pressed down
Default Settings
Initializing Settings
Setting Transition Charts p.158