Positioning
65
ZX2 User’s Manual
INTRODUCTION
BASIC
SETUP
PREPARATION
FOR
MEASUREMENT
TROUBLE-
SHOOTING
INDEX
CONTENTS
SETTING
TRANSITION
CHARTS
FLOW OF
OPERATION
MAIN
APPLICATIONS
& SETTING
METHODS
DETAILED
SETTINGS
SPECIFI-
CATIONS
Height
Double
Sheet
Detection
Positioning
Eccentricity
and Surface
Deflection
Steps
and
Warpage
Thickness
6
Threshold Setting
7
Return to RUN mode
*
For details on optimizing settings, such as output and input, see "DETAILED
SETTINGS."
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Press the button to display
the HIGH threshold.
(Setting example)
Non-defective product
position 49 to 51 mm
Set the positioning MAX and
MIN distances to the HIGH
and LOW thresholds,
respectively.
* If the button is pressed
when the cursor is at the
right-most digit or the
button is pressed when the
cursor is at the left-most digit,
the setting will be canceled.
* Set so that the HIGH
threshold is greater than the
LOW threshold.
Press the button to enable
setting of the HIGH threshold.
Set any value.
Press the
button to move
the digit, press the button to
change the numeric value, and
set the HIGH threshold.
Press the
button to apply
the setting.
Press the button to display
the LOW threshold.
Press the button to enable
setting of the LOW threshold.
Set any value.
Press the
button to move
the digit, press the button to
change the numeric value, and
set the LOW threshold.
Press the
button to apply
the setting.
Button
Operation
Display
Description of Operation
Explanation of
Selection Menu
Hold down the
button for
three seconds to switch to the
RUN mode.
Required
Setting the HIGH and LOW thresholds set the
range of measured values judged as PASS.
Press to display
.
Lit
H
P
L
51
49
Press to set.
[Change numeric value]
[Move digit]
Press to display
.
Lit
P
di l
Press to set.
[Change numeric value]
[Move digit]
Required
Switch to the mode in which
measurement is performed.
Hold down for
3 seconds
Out