Table 34.
POWER UP SEQUENCE
Definition
Symbol
Minimum
Typical
Maximum
Unit
V
DD
_PLL to V
AA
/V
AA
t0
0
100
–
μ
S
V
AA
/V
AA
_PIX to V
DD
_IO
t1
0
100
–
μ
S
V
DD
_IO to V
DD
t2
0
100
–
μ
S
V
DD
to V
DD
_SLVS
t3
0
100
–
μ
S
Xtal Settle Time
tx
–
30
(Note 1)
–
mS
Hard Reset
t4
1
(Note 2)
–
–
mS
Internal Initialization
t5
150000
–
–
EXTCLKS
PLL Lock Time
t6
1
–
–
mS
1. Xtal settling time is component-dependent, usually taking about 10 – 100 mS.
2. Hard reset time is the minimum time required after power rails are settled. In a circuit where Hard reset is held down by RC circuit, then the
RC time must include the all power rail settle time and Xtal settle time.
3. It is critical that V
DD
_PLL is not powered up after the other power supplies. It must be powered before or at least at the same time as the
others. If the case happens that V
DD
_PLL is powered after other supplies then sensor may have functionality issues and will experience high
current draw on this supply.
Power-Down Sequence
The recommended power-down sequence for the AR0331
is shown in Figure 47. The available power supplies
(V
DD_
IO, V
DD
, V
DD_
SLVS, V
DD
_PLL, V
AA
, V
AA
_PIX)
must have the separation specified below.
1. Disable streaming if output is active by setting
standby R0x301a[2] = 0
2. The soft standby state is reached after the current
row or frame, depending on configuration, has
ended
3. Turn off V
DD
_SLVS
4. Turn off V
DD
5. Turn off V
DD
_IO
6. Turn off V
AA
/V
AA
_PIX
7. Turn off V
DD
_PLL
Figure 47. Power Down
V
DD
_IO (1.8/2.8)
t4
t 0
t1
t3
EXTCLK
V
DD
_SLVS (0.4)
V
DD
(1.8)
V
AA
_PIX
(2.8)
V
DD
_PLL (2.8)
Power Down until next Power up cycle
t2
V
AA