6.5 ISO1800-6B Read and Write 

For this module is to read and write 1800-6B card number. 
 

Identify

When click, the card in the reader Hex number will display here. 

 

Read: 

When  click  read,  the  related  address  and  length  Hex  number  will  display,  for 

example the card number is    E0-04-00-00-3F-0B-22-07-00-00-00-00,   

Address 

0

, length 2: 

E0-04,

 length is 3, then E0-04-00 

Address 

1

., length 2:

04-00 

Address 

2

, length 2: 

00-00

 

... 

 

Write: 

When click write, will write the related Hex to related address.For example the card 

number is E0-04-00-00-3F-0B-22-07-00-00-00-00, 

Address is 

0

 and length is

 2

, and write 

01-02 

to the address, then the card no. Become 

 

01-02

-00-00-3F-0B-22-07-00-00-00-00, 

If write to address 

and the length is 2. 

Then card number become 

E0-01-02-00-3F-0B-22-07-00-00-00-00

 

 

Summary of Contents for 2E-2656

Page 1: ...UHF Reader User Manual 2E 2656 2E 2657...

Page 2: ...tion 9 6 Quick Start for Software 9 6 1 Connect reader With PC 9 6 1 1 RS232 Communication 10 6 1 2 TCP IP Communication 10 6 2 Basic Settings 12 6 2 1 Wiegand Parameter Input Zone 12 6 2 2 Basic Para...

Page 3: ...tributor or sales department See below picture for the inside package and separate products picture 2E 2656 Interface RS232 485 RS232 485 Size 227 227 60MM 450 450 70MM Voltage DC12V 300MA DC12V 300MA...

Page 4: ...scription Picture Device RS232 Serial Port Cable 12V Adapter Antenna Bearer 3 Wiring Diagram Wire No Color Functio n Description Model 1 Red DC9 15 V Positive 2E 2656 57 2 Black GND Negative 2E 2656 5...

Page 5: ...stallation In general there are two installation ways of UHF reader see blow picture 1 and 2 7 2E 2656 57 2E 2656 57 PIN5 8 Grey Trigger 2E 2656 57 9 Orange 485 2E 2656 57 10 Purple 485 2E 2656 57 TCP...

Page 6: ...2 Mounting reader and height adjustment For installation 1 the mounting pole diameter should be 50 60mm height should be 2 2m we suggest to use the stainless steel material thickness greater than 1 2...

Page 7: ...3 5 4m 4 3 Reader Installation Angle Adjustment See below picture 3 and 4 for reference adjust angle for reader 3 4 4 4 Installation Example Parking Lot Principal to install the reader 1 Reader and ba...

Page 8: ...osition The principal of the tag position is not cover the eyesight of driver Suggest Position If reader install in left side then suggest A and E position If reader install in the top then suggest B...

Page 9: ...ard to read Correct Hold Card Wrong Hold Card 5 Application 1 Transport Control 2 Vehicle Management 3 Parking Management 4 Access Control Management 5 Product Anti fake Detection 6 Anti thief Managem...

Page 10: ...d rate then click connect 6 1 2 TCP IP Communication For TCP IP communication you need open two client Netconfig exe and RFIDDemo3203 exe Netconfig exe to get the IP address and port of connected UHF...

Page 11: ...4 If communication OK see below...

Page 12: ...02 03 04 05 06 07 i s 8 byte the parameter is this 3 byte when the value is 0 it is E0 01 02 when the value is 1 It is 01 02 03 More details please refer to Wiegand protocol Output Period It is freque...

Page 13: ...and26 It is standard reader communication mode one way communication mode Wiegand34 It is standard reader communication mode one way communication mode Read Interval The speed of reading card Note rea...

Page 14: ...set to read the length of other area data in senior parameter the max Is 12 bytes 5 ISO18000 6B EPC GEN 2 ISO18000 6B and EPC GEN 2 protocol tag can be read Freq Parameters Input Zone It refer to 180...

Page 15: ...2 Choose then Enabled and set password then set Parameters Set Para...

Page 16: ...ow put the tag on the reader the reader is not beep 4 Presses Encrypt Tag until the reader beep then encrypt succeed Note when the encrypt tag you can move the tag to accelerate the process of encrypt...

Page 17: ...ure if display red in status bar 6 2 8 Default All Click Default All button basic parameter and senior parameter will recover to default Need to click parameter setup updated parameter will be set in...

Page 18: ...e card number is 01 02 03 04 05 06 08 09 10 11 12 Address 2 length 2 01 02 length is 3 then 01 02 03 Address 3 length 2 03 04 Address 4 length 2 05 06 Write When click write will write the related Hex...

Page 19: ...0B 22 07 00 00 00 00 Address 0 length 2 E0 04 length is 3 then E0 04 00 Address 1 length 2 04 00 Address 2 length 2 00 00 Write When click write will write the related Hex to related address For exam...

Page 20: ...hen reader use external power supply must connect the common ground with the controller or the device you connect with 4 For the reader we suggest 9 15v power supply you d better use the power supply...

Reviews: