IX. Filter Assembly
Caution:
If exhaust air is vented outside you must provide make up / return air.
Flue gases (carbon monoxide) can be drawn into the shop from furnaces,
water heaters or other appliances.
1. Exhaust air to exterior of building.
Mount directly at the hole in exterior
wall or use a square-to-round transition
and ductwork to vent air to exterior.
No Filter Assembly
Note: Do not return exhaust air to the shop unless filter media is added.
10
2 HP Commercial Wood Dust Collector Owners Manual
O.A.S. 2004
c
External Filter Assembly 39
1. Attach cartridge with four bolts provided. See Fig. 1
2. If Filter requires additional support. Use the plate at the
top of the filter to support the filter assembly.
Note: If filter cartridge is located away from the cyclone
and motor, additional square-to-round connectors and pipe
can be purchased.
Fig. 1
*Silencer Included.
Do not
remove foam
from around
wire cage!
This is part of
silencer!
For Filter cleaning instructions, see pg. 14.
Do NOT
remove
acoustic
foam from
cage.
Included
Silencer
Do NOT remove
fabric strap from
filter.