background image

XIII.  Terms and Conditions

  Please look over the shipped order very carefully in the presence of the delivery person for damage or
incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping
packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive concealed
damage. The shipping company will not take responsibility if the damage is not noted on the delivery receipt.
In the event of shipping damage, call O.A.S. immediately so we can expedite replacements. Please check
in all parts within 3 days from receiving order. Notify O.A.S. immediately of any missing or incorrect parts.
O.A.S. does not accept any claims for damage or shortage after 3 days from date of delivery.

Checking in Order

  Oneida Air Systems warrants products it manufactures for a period of 2 years to the original purchaser from
the date of purchase. Items not manufactured by O.A.S. are limited to their own manufacturer’s warranties.
This warranty does not apply to defects due directly or indirectly to misuse, negligence, accidents, abuse,
repairs, or alterations or lack of maintenance. This is Oneida Air Systems sole written warranty and any and
all warranties that may be implied by law, including any merchantability or fitness, for any particular purpose,
are hereby limited to the duration of this written warranty. O.A.S. does not warrant or represent that the
merchandise complies with the provisions of any law or acts unless the manufacturer so warrants. In no
event shall O.A.S.’s liability under this warranty exceed the purchase price paid for the product and any legal
actions brought against Oneida Air Systems shall be tried in the State of New York, County of Onondaga.
  Oneida Air Systems shall in no event be liable for death, injuries to persons or property or for incidental,
contingent, special, or consequential damages arising from the use of our product.
  Oneida Air Systems does not warrant or authorize use of wood dust collectors for other purposes. This
includes wood products that are treated, coated, or otherwise altered from their natural state.

Limited Warranty

  Products will be shipped to Buyer’s single destination. Title and risk of loss shall pass to the Buyer upon
delivery to such destination. Buyer pays transportation expenses. Dates of shipment are advisory and O.A.S.
will make reasonable efforts to ship on or before the date states for shipment, however, O.A.S. shall not incur
any liability for failure to ship on that date.

Delivery Risk of Loss

  Buyer must inform O.A.S. of any shortage or damage, by so noting in writing, on the freight delivery bill prior
to signing to indicate receipt of shipment. All claims, including claims covered under the limited warranty, are
subject to inspection and investigation by O.A.S.. O.A.S. reserves the right to inspect and investigate all
returned products before Buyer’s claim is settled. All products returned for a cash refund must be unused,
resaleable and purchased within the last six months. There are no refunds on flex hose or custom made
components. 

There will be a 25% restocking fee applied to any returned items.

Returned Goods Policy

O.A.S. 2002

c

5 - 7.5 HP Direct Drive Owner’s Manual

15

Summary of Contents for 5 & 7.5 HP Direct Drive Cyclonic Dust Collectors

Page 1: ...5 7 5 HP Direct Drive Cyclonic Dust Collectors Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual...

Page 2: ...e ofContents Page Read the entire Owner s Manual before installing or operating system I II III IV V VI VII VIII IX X XI XII XIII XIV 2 3 4 5 6 7 8 8 9 10 11 12 13 14 15 System Start Up Information Di...

Page 3: ...nual 4 Have a licensed electrician check current draw on motor with all gates open Current draw should not exceed maximum motor amperage OAS is not responsible for destroyed motors Caution The Direct...

Page 4: ...gases carbon monoxide can be drawn into the shop from furnaces water heaters or other appliances 2 External Cartridge Filters 3 External Tube Filter O A S 2002 c 5 7 5 HP Direct Drive Owner s Manual...

Page 5: ...filter media BIA ZHI 487 test Rated G Captures 99 of test material over 20 microns Captures 99 5 of test material between 0 2 2 0 microns 11 fpm face velocity Tube Filter Bags 2 Pleated Cartridges 260...

Page 6: ...39 1 4 62 73 1 8 12 12 32 1 8 O D of Mounting Ring 69 875 24 1 4 Bolt Holes 30 3 8 10 031 I D 7 64 I D 1 25 Flange Tube Filters Height for 8 bags Other heights available 131 w 55 gal steel drum 105 No...

Page 7: ...race for Cyclone Angle Ring to sit on 1 Choose the system orientation plenum can be on the right or the left of the cyclone Bolt together the stand using the cross bars and 3 8 x 1 bolts Note the cros...

Page 8: ...iron ring will be on top of the cross bars of the stand Put bead of silicone around inside edge of flange on the cyclone cone Then put bolt through flat washer then bolt through holes in both flanges...

Page 9: ...ocedures could result in serious injury or death Disconnect all power and discharge all capacitors before servicing Install and ground per local and national codes Consult a licensed electrician with...

Page 10: ...n plastic bucket and tube filter to fit properly underneath A well sealed plywood box will make a good plenum for air distribution through the tube filters Use plywood for the plenums Cut 12 dia holes...

Page 11: ...ring the blow off process Let dust settle into dust pan Unclip and dump out dust Filter removal is not required You can also run your fingers around the filter pleats to knock material down WARNING A...

Page 12: ...licensed electrician Ground Connect house ground wire to green chassis screw in motor wire housing box Motor Wire Box Green Chassis Screw 11 Top View Outlet Inlet O A S 2002 c 5 7 5 HP Direct Drive O...

Page 13: ...5 and 7 5hp direct drive dust collectors do not come wired or with an on off switch Because of the voltage and amperage requirements of the system an industrial switch must be used OAS offers Square...

Page 14: ...nd as a sealant Check for air leaks between collector and dust bin Close all unused blast gates at your woodworking machines Examine hood design for weaknesses according to the ductwork guide Check fo...

Page 15: ...elow 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an e...

Page 16: ...warrants In no event shall O A S s liability under this warranty exceed the purchase price paid for the product and any legal actions brought against Oneida Air Systems shall be tried in the State of...