1. Fill at least 2/3 of the stainless steel tank with a cleaning solution. Based on cleaning

requirements, a small amount of cleaning solution is recommended because it will
help to increase the cleaning performance.

2. Dismantle the spare parts to be cleaned as possible as you can, and remove the dirt,

oil contaminants, carbon deposit etc with a high-pressure jet, wire brush,scraper
knife or other tools so as to prolong the service life of the cleaning solution and
ensure the cleaning speed and performance.

3. Put the spare parts to be cleaned into the tank and make them fully-immersed, but

not overlapped as possible as you can.

4. Start ultrasonic cleaning:

A. Connect the power socket on the back to a power with the power cord (the red
indicator will turns on and the LED screen will display “180”.)
B. Press the “TIME” button to switch the cleaning time in the following time

circulation:

90

→ 120→ 150→ 180→ 210→ 240→ 270→ 300→ 330→ 360→ 540→

720→ 900→18. →21. →24. →27. → 30.→ 90 (18 cleaning time in total).

C. Press “ON/OFF” button once to make the machine start cleaning. The blue ultrasonic

indicator turns on, the setting time starts counting down. When the time reaches “886”,

the machine stop working automatically. Besides, the ultrasonic cleaning can also be

stopped by pressing “ON/OFF” once again.

D. Unplug the power cord, pour the cleaning solution, clean the tank and the housing

with a clean cloth.

5. In order to enhance the cleaning effect, you can add appropriate amount of detergent

into the cleaning solution or prolong the cleaning time.

6. The machine will stop working after 45 minutes continuous work, and can started

working again after 4 minutes’ break.

Summary of Contents for OZL-800

Page 1: ...ess steel tank Thank you for purchasing this ultrasonic cleaner Please take some time to read these operating instructions before use and keep them for future reference Failure to follow these instructions may lead to serious artificial damages to the product ULTRASONIC CLEANER OZL 800 USER MANUAL ...

Page 2: ... and other militaria Ultrasonic cleaning is not recommended to be used to clean the following gemstones Opal Pearl Emerald Tanzanite Malachite Turquoise Lapis and Coral Ultrasonic cleaning is based on the cavitation effect caused by high frequency ultrasonic wave vibration signal in the fluid Microscopic bubbles are formed and then implode violently causing the cavitation which create an intense s...

Page 3: ... with the power cord the red indicator will turns on and the LED screen will display 180 B Press the TIME button to switch the cleaning time in the following time circulation 90 120 150 180 210 240 270 300 330 360 540 720 900 18 21 24 27 30 90 18 cleaning time in total C Press ON OFF button once to make the machine start cleaning The blue ultrasonic indicator turns on the setting time starts count...

Page 4: ...nnection and plug the power lord B Change the burned fuse with a good one of the proper voltage C Connect or change the high frequency wire D Check the circuit or consult our after sale service department E Find out the defective component replace it or ask our after sale service department for a new circuit board 2 The time setting does not work A The timer is broken B Other reasons A Reset the p...

Reviews: