Precision Flow Measurement
An ON
I
CON Brand
AG90 Propeller Replacement
Quick Start Guide
253.872.0284
Page 1 of 4
seametrics.com
Warnings
Warnings
•
Confirm that U-clip retainer is installed and never remove the
U-clip retainer when pipe is under pressure—may result in
serious injury.
•
Saddle bolts must be tightened evenly. Do not over tighten.
•
Install security seals during installation if regulations require.
•
Improper sealing of cables or cable glands will void warranty.
•
Ensure proper grounding when required.
•
Programming pipe ID, pipe insertion hole size and straight pipe
configuration is required for the meter to read.
•
To prevent tampering or changes to the program, after initial
set-up, either enter a security pass-code, or remove the display
lid and place a security tab over one of the arrows before
installing the housing security seal.
Refer to instruction manual for further details.
Recommended Tools
Recommended Tools
Recommended:
•
3/32” or 2.5mm (small) flat head screw driver
•
Crescent Wrench
•
5/32” Hex Key
Optional:
•
Channel locks
•
6” Strap Wrench
Check Components
Check Components
Optional
Optional
Display Security Seal
Cable Gland
Security Clip & Seal
(Security Clip has small hole for seal wire)
Meter with Indicator
and hinged cover
Saddle Assembly
(Packaged Separately)
Saddle Gasket
Power/Output Cable
Security Tab