background image

LT-14494 r2.5 20200130

1/30/2020

Seametrics • 19026 72nd Avenue South • Kent, Washington 98032 • USA 

(P) 253.872.0284 • (F) 253.872.0285 • 1.800.975.8153 • seametrics.com 

AG90 Propeller Replacement

Quick Start Guide

Choose a position that will minimize flow distortion. 

Positioning

Positioning

1. Clean the mounting surface, removing 

1. Clean the mounting surface, removing 

any roughness which would prevent 

any roughness which would prevent 

the gasket from sealing. Place gasket 

the gasket from sealing. Place gasket 

centered over pipe opening.

centered over pipe opening.

2. Place saddle top over gasket.

2. Place saddle top over gasket.

3. 

3. Make sure saddle top covers entire 

Make sure saddle top covers entire 

gasket.

gasket.

1

st

4

th

3

rd

2

nd

4. Place the saddle clamps under 

4. Place the saddle clamps under 

the pipe and align with the clamp 

the pipe and align with the clamp 

guides on the saddle top. 

guides on the saddle top. 

6. Insert the AG90 sensor into the saddle 

6. Insert the AG90 sensor into the saddle 

fitting and secure with mounting clip or 

fitting and secure with mounting clip or 

attach security clip and seals if required.

attach security clip and seals if required.

5. Place saddle plates over saddle 

clamp threads. Attach nuts and 

tighten as shown below. Torque to 75 

ft-lb in cross pattern.

BEFORE INSTALLING

 measure & record inside diameter (ID) of pipe.

*10X/5X

2X

Flow

Flow

Flow

Flow

Flow

Flow

Upstream straight pipe is selected during initial setup. Upstream 

options are 5X or 10X the diameter and are based on the 

amount of straight pipe available in either new or propeller meter 

replacement installation. Downstream straight pipe requirement 

is 2X the diameter. See programming setup for details.

Choose a position that will ensure a full pipe. 

Side (3 o’clock) and top 

(12 o’clock) installations 

are acceptable.

 

1. If you have the bolt-in, 3-vane style they may be removed or left in place.  They do not affect performance.

 2. If you have the 6-vane, bolt-in style with a cone, it should be removed.
 3. For 6-vane, weld-in style installed in a spool, turn the spool 180° and reinstall with the vanes behind the meter.
 4. Orifice, tube or Vortab style conditioners will not affect performance.

Flow Straightening Vanes/Conditioners

NOTE: Gasket will extend 

NOTE: Gasket will extend 

outside of a 4” pipe 

outside of a 4” pipe 

saddle’s sides.

saddle’s sides.

Summary of Contents for SeaMetrics AG90

Page 1: ... straight pipe configuration is required for the meter to read To prevent tampering or changes to the program after initial set up either enter a security pass code or remove the display lid and place a security tab over one of the arrows before installing the housing security seal Refer to instruction manual for further details Recommended Tools Recommended Tools Recommended 3 32 or 2 5mm small f...

Page 2: ...h mounting clip or attach security clip and seals if required attach security clip and seals if required 5 Place saddle plates over saddle clamp threads Attach nuts and tighten as shown below Torque to 75 ft lb in cross pattern BEFORE INSTALLING measure record inside diameter ID of pipe 10X 5X 2X Flow Flow Flow Flow Flow Flow Upstream straight pipe is selected during initial setup Upstream options...

Page 3: ...applied See Instruction manual for details With No External Output If not using external output no wiring is required White C1 Pulse Green C1 Pulse C1 With Pulse Output Only Pulse with External DC Power Source 9 36 VDC at 250mA max 30mA average 9 36 VDC at 250mA max 30mA average White C1 Pulse Green C1 Pulse C1 Red C1 DC Black C1 DC Clamp cable with strain relief clips Attach drain wire lug to bra...

Page 4: ...s Increase sampling interval to extend battery life May vary depending on environmental factors See instruction manual for more details SAMP SETEX EXIT INFO PRESS TO SET OUTER WALL DIAMETER AND WALL THICKNESS SETUP SAMP SETUP EXIT ID INFO PRESS AND TO CHANGE SAMP SETUP EXIT HOLE INFO PRESS AND TO CHANGE SAMP SETUP EXIT PRESS TO EXIT MENU AND RETURN TO FLOW DISPLAY INFO SAMP SETUP EXIT PIPE INFO PR...

Reviews: