AG90 Propeller Replacement

Quick Start Guide

Wiring

Wiring

Unscrew the display lid and remove it from the meter. Unsnap the display assembly and remove it from the meter 

exposing the internal wiring connector. Install the wires through the cable glands into the 2 pin screw connector. 

(C1 = power/output cable)

   

EXTERNAL POWER WARNING! 

Ribbon cable must be connected 

BEFORE

 external power is applied. See Instruction manual for details.

With No External Output - If not using external output, no wiring is required.

White (C1) Pulse-

Green (C1) Pulse+

C1

With Pulse Output Only

Pulse with External DC Power Source

9 - 36 VDC at 250mA max, 30mA average

9 - 36 VDC at 250mA max, 30mA average

White (C1) Pulse-

Green (C1) Pulse+

C1

Red (C1) DC+

Black (C1) DC-

Clamp cable with strain relief 

clips. Attach drain wire lug to 

bracket post.

Remove plug & o-ring. Insert 

cable gland/strain relief. Feed 

cable through cable gland.

CRITICAL! 

 

Torque cable gland sealing  

nut to 22 in-lbs.

WARNING: 

Improper sealing of glands or cables will invalidate any warranty.

If plugs or cable glands are removed, reinstall using Teflon pipe sealant, or 

tape, to ensure maximum moisture protection.

Summary of Contents for SeaMetrics AG90

Page 1: ... straight pipe configuration is required for the meter to read To prevent tampering or changes to the program after initial set up either enter a security pass code or remove the display lid and place a security tab over one of the arrows before installing the housing security seal Refer to instruction manual for further details Recommended Tools Recommended Tools Recommended 3 32 or 2 5mm small f...

Page 2: ...h mounting clip or attach security clip and seals if required attach security clip and seals if required 5 Place saddle plates over saddle clamp threads Attach nuts and tighten as shown below Torque to 75 ft lb in cross pattern BEFORE INSTALLING measure record inside diameter ID of pipe 10X 5X 2X Flow Flow Flow Flow Flow Flow Upstream straight pipe is selected during initial setup Upstream options...

Page 3: ...applied See Instruction manual for details With No External Output If not using external output no wiring is required White C1 Pulse Green C1 Pulse C1 With Pulse Output Only Pulse with External DC Power Source 9 36 VDC at 250mA max 30mA average 9 36 VDC at 250mA max 30mA average White C1 Pulse Green C1 Pulse C1 Red C1 DC Black C1 DC Clamp cable with strain relief clips Attach drain wire lug to bra...

Page 4: ...s Increase sampling interval to extend battery life May vary depending on environmental factors See instruction manual for more details SAMP SETEX EXIT INFO PRESS TO SET OUTER WALL DIAMETER AND WALL THICKNESS SETUP SAMP SETUP EXIT ID INFO PRESS AND TO CHANGE SAMP SETUP EXIT HOLE INFO PRESS AND TO CHANGE SAMP SETUP EXIT PRESS TO EXIT MENU AND RETURN TO FLOW DISPLAY INFO SAMP SETUP EXIT PIPE INFO PR...

Reviews: