EX90 Propeller Replacement

Quick Start Guide

253.872.0284 

Page 1 of 4 

seametrics.com 

Recommended Tools

Recommended Tools

Recommended:

• 

3/32” or 2.5mm (small) flat head screw driver

• 

Crescent Wrench

•  5/32” Hex Key

Optional:

• 

Channel locks

• 

6” Strap Wrench

Warnings

Warnings

• 

Confirm that U-clip retainer is installed and never remove the 

U-clip retainer when pipe is under pressure—may result in 

serious injury.

• 

Saddle bolts must be tightened evenly. Do not over tighten.

• 

Install security seal during installation if regulations require. 

• 

Improper sealing of cables or cable glands will void warranty.

• 

Ensure proper grounding when required.

• 

Programming pipe ID, pipe insertion hole size and straight pipe 
configuration is required for the meter to read. 

Refer to instruction manual for further details.

Check Components

Check Components

Optional

Optional

Display Security Seal

Cable Gland

U-clip Retainer

Meter with Indicator 

and hinged cover

Saddle Assembly

(Packaged Separately)

Saddle Gasket

Power/Output Cable

Summary of Contents for SeaMetrics EX90

Page 1: ... result in serious injury Saddle bolts must be tightened evenly Do not over tighten Install security seal during installation if regulations require Improper sealing of cables or cable glands will void warranty Ensure proper grounding when required Programming pipe ID pipe insertion hole size and straight pipe configuration is required for the meter to read Refer to instruction manual for further ...

Page 2: ...e the saddle clamps under the pipe and align with the clamp the pipe and align with the clamp guides on the saddle top guides on the saddle top 6 Insert the EX90 sensor into the saddle 6 Insert the EX90 sensor into the saddle fitting and secure with U clip and seal if fitting and secure with U clip and seal if required required 5 Place saddle plates over saddle clamp threads Attach nuts and tighte...

Page 3: ...applied See Instruction manual for details With No External Output If not using external output no wiring is required White C1 Pulse Green C1 Pulse C1 With Pulse Output Only Pulse with External DC Power Source 9 36 VDC at 250mA max 30mA average 9 36 VDC at 250mA max 30mA average White C1 Pulse Green C1 Pulse C1 Red C1 DC Black C1 DC Clamp cable with strain relief clips Attach drain wire lug to bra...

Page 4: ...s Increase sampling interval to extend battery life May vary depending on environmental factors See instruction manual for more details SAMP SETEX EXIT INFO PRESS TO SET OUTER WALL DIAMETER AND WALL THICKNESS SETUP SAMP SETUP EXIT ID INFO PRESS AND TO CHANGE SAMP SETUP EXIT HOLE INFO PRESS AND TO CHANGE SAMP SETUP EXIT PRESS TO EXIT MENU AND RETURN TO FLOW DISPLAY INFO SAMP SETUP EXIT PIPE INFO PR...

Reviews: