![background image](http://html.mh-extra.com/html/online-electronics/id5000a/id5000a_operating-manual_1638140008.webp)
ONLINE ELECTRONICS LTD
ID5000A_5001_A03
Page 7 of 21
1 6 : 0 8 : 5 5 2 8 / 0 4 / 1 5
P I P E D I A M E T E R 0 2 8 c m
S T O R E D E V E N T S 0 0 9
L S T 2 8 / 0 4 / 1 5 1 6 : 0 0 : 0 5
S T O R E D G A I N 9 9
I N D D E L A Y 0 0 : 1 0 : 5 9
D E T E C T I O N C O U N T 5 0
4
2 8 / 0 4 / 1 5 1 6 : 0 8 : 5 5
EVENT064
28/04/15
16:00:05
5
3.3.
SINGLE BUTTON MENU INTERFACE
While in DETECTION MODE 0, the control button can be pressed at any point to enter the
menu interface. While in the menu interface, the unit will ignore all pig passages. From the
menus the user can configure several parameters which are discussed in this section.
To enter the menu interface from SETUP MODE 1 a long press on the control button is required
as per section 3.4 SETUP MODE 1.
Note that the menus entered from DETECTION MODE 0 and SETUP MODE 1 contain different
items. All items are covered by the following sections and each section indicates whether the
item is accessed from DETECTION MODE 0 or SETUP MODE 1.
While in the menu system, every time the user presses the control button the => cursor will
move down one line and the timer at the bottom left of the screen will be reset to 5. Once the
cursor is pointing at the desired item the user simply allows the timer to reach 0 and the
selected item will be executed. This simple behaviour is used throughout the menu interface to
modify settings and interact with the unit.
To modify parameters, simply follow the instructions provided on the screen. All parameters
are incremented by pressing the control button until they are at the desired value then
allowing the timer to reach 0.
If you do not wish to modify a parameter then simply allow the timer to reach 0 without
operating the control button. The menu system is designed so that the unit will always EXIT if
the control button is left released for a long enough time.
3.3.1.
STATUS
Accessed from DETECTION MODE 0. Selecting this item
shows current time and date, pipe diameter detected, the
number of stored events, the date and time of the last
event, stored gain value, current indicator delay, and the
detection counter setting.
When the counter indicator reaches zero the screen will go
blank and the unit will start looking for a pig passage
again. If the user wants to pause the screen to read it they can press and hold the switch to
pause the timer.
3.3.2.
VIEW EVENTS
Accessed from DETECTION MODE 0. Selecting this item
allows the user to scroll through logged event data. If no
data has been logged then a NO EVENTS message will be
displayed.
The events are displayed one at a time from newest to
oldest. At the very top of each display the current date and
time are shown. Below this the event number is shown with
the event date and time. If the switch is pressed before the counter reaches zero the screen
will show the next event. If the counter reaches zero then the display will switch off and the
unit will return to DETECTION MODE 0.