TECHNICAL DATA
18 / 22
Y500-1500_usermanual_engl_updated_202001.docx
9.
Technical data
9.1 Specification
Model
YUNTO
500
YUNTO
800
YUNTO
1200
YUNTO
1500
Order no.
Y500
Y800
Y1200
Y1500
Electrical characteristics
Rated power (VA / W)
500 / 300
800 / 480
1200 / 720
1500 / 900
Input voltage and toler-
ance in normal mode
230V (180
– 270V)
Frequency
50 / 60Hz (automatic detection) +/-5Hz
Max. input current
3.3A
5.2A
7.8A
9.7A
Cold-start function
Yes
Output voltage
230V +/-10%
Output frequency
Battery operation
50 / 60Hz +/-1Hz
Wave form
Simulated sine
Efficiency,
Normal operation
>95%
Battery mode
70%
Power loss, max.
15W
24W
36W
45W
Connections
Input
1x IEC320 C14 (10A)
Outputs, 10A
3x IEC320
C13 (10A)
3x IEC320
C13 (10A)
5x IEC320
C13 (10A)
5x IEC320
C13 (10A)
Batteries
Typ. Autonomy times at
50 and 100% load and
pf=0.6
6 / 3
6 / 2.5
6 / 3
6 / 2.5
Battery type
1x 12V /
7Ah
1x 12V /
9h
2x 12V /
7Ah
2x 12V /
9Ah
Design
Sealed, maintenance-free, valve-controlled,
lead/acid, life expectancy 3 to 5 years in accordance
with EUROBAT
Charge current
0.5A
Charging time
< 8 hours to 90%
Communication
USB
Yes
Modem / Network
Over-voltage protection
Yes