background image

Onnline Thermostat 105 for Floor Heating

Onnline Thermostat 105 is an electronic thermostat with an
external floor sensor and a built in temperature sensor so it can
be used as room thermostat or floor heating system controller.

-

,

1.SPECIFICATION:

Power source:

/- 10%

Hz

Hz

Relay contact:

250VAC 16A

Temperature setting range:

5

to

Limit of temperature:

Color

White

;

/

:

50

60

35

0-10

27

℃(

+ ℃

)

2.IMPORTANT SAFETY INFORMATION:

Only professional contractor should install this thermostat

Read all of the information in this manual before installing

the thermostat.

Always turn off power at the main power source by

unscrewing fuse or switching circuit breaker to the off

position before installing, removing, cleaning, or servicing

this thermostat

All wiring must conform to local and national building and

electrical codes and ordinances.

Maximum floor temperature has to be limited to be 27

and

the sensor has to be set as Fig 3 (Both senor) when it is

applied on wooden floor.

3.INSTALLATION:

Mounting of thermostat

1. Lift off the front cover as Fig.2.

2. Follow the wire diagram above for the electrical connection.

3. Put the thermostat

circuit board

to the wall box and

screw it into the wall

4. Mount the wall frame, fit the cover in place and press so that

the fastening hooks snap into place and make sure that the

temperature knob is correctly placed. Please refer to the fig 3.

(

)

.

Fig. 2

Choosing the sensor

.

.

has a built-in sensor and terminals for

connecting an external sensor as main sensor or min/max limiting

sensor. The three working modes of the thermostat are controlled

by the terminal points: K1 and K2 on the circuit board Make

sure that the power is off before the adjustment is taken

Onnline thermostat 105

1. External sensor only factory setting

Fig. 1

(

)

(

)

When the external sensor doesn’t work, the thermostat will

connect the inner sensor automatically. When neither of the

sensors works,the thermostat will go to safe mode automatically.

Only connect K2. External sensor is used as main sensor.

2. Inner sensor only

Fig. 2

(

)

Connect both K1 and K2. Only inner sensor is used.

When the inner sensor doesn’t work, the thermostat will go to

safe mode automatically.

3. Both sensors Fig. 3

(

)

(

with maximum temperature limiting function)

Connect neither of the points. Both sensors are used

The inner sensor works as temperature controlling sensor while

the external sensor works as the temperature limiting sensor.

No matter how to adjust the set-point on knob, the temperature

of the sensor will be limited to be under 27

. When one of the

sensors doesn’t work, the thermostat will go to safe mode

automatically and the maximum working power will just be

80% of the original one.

EMC emissions & immunity standards:

This product meets the requirement of European Council s

directive 89/336, EN61000-6-3, EN

and it carries

CE marking

This product meets the requirements of European LVD 73/23,

EN60730-1 and EN60730-2-9.

'

.

61000-6-2

LVD

Wire Diagram (fig.1)

Turn the handle clockwise

to tighten it.

Make the 10 on the dial point

at “

“ , then press it down.

Setting the temperature knob in place (fig.3):

Heating load

Temperature sensor

1
2

1

2

Onnline