Compute Box Power output (Device connector)
Minimum Typical Maximum Unit
Output voltage
-
24
25
[V]
Output current
-
4.5
4.5*
[A]
* Peak currents
8.1.3.2. Compute Box I/O interface
Power Reference (24V, GND)
Minimum
Typical
Maximum
Unit
Reference output voltage
-
24
25
[V]
Reference output current
-
-
100
[mA]
Output (DO1-DO8)
Minimum
Typical
Maximum
Unit
Output current - altogether
-
-
100
[mA]
Output resistance (active state)
-
24
-
[Ω]
Input (DI1-DI8) as PNP
Minimum
Typical
Maximum
Unit
Voltage level - TRUE
18
24
30
[V]
Voltage level - FALSE
-0.5
0
2.5
[V]
Input current
-
-
6
[mA]
Input resistance
-
5
-
[kΩ]
Input (DI1-DI8) as NPN
Minimum
Typical
Maximum
Unit
Voltage level - TRUE
-0.5
0
5
[V]
Voltage level - FALSE
18
24
30
[V]
Input current
-
-
6
[mA]
Input resistance
-
5
-
[kΩ]
8.2. Mechanical Drawings
8.2.1. Adapter Plate
No adapter plate is required.
HARDWARE SPECIFICATION
69
Summary of Contents for 2FGP20
Page 1: ...USER MANUAL FOR UR ROBOTS v1 13 0 Original Instructions...
Page 62: ...Illustration Pad position Maximum force N 2 200 3 100 4 400 HARDWARE SPECIFICATION 62...
Page 71: ...8 2 3 Tools 8 2 3 1 2FGP20 All dimensions are in mm and inches HARDWARE SPECIFICATION 71...
Page 79: ...12 Certifications CERTIFICATIONS 79...
Page 80: ...12 1 EMC 12 2 2FGP20 Environment CERTIFICATIONS 80...
Page 81: ...12 3 Declaration of Incorporation 12 3 1 2FGP20 CERTIFICATIONS 81...