HOBO
MicroRX
Station
for
HOBOnet
(RX2105
and
RX2106)
Manual
1
‐
800
‐
LOGGERS
7
www.onsetcomp.com
b.
Install
the
batteries
in
the
mote
and
press
the
button
on
the
mote
for
3
seconds.
c.
Watch
the
mote
LCD
during
the
process
of
joining
the
network.
Note:
If
the
mote
cannot
find
the
network
or
has
trouble
remaining
connected
during
this
process,
make
sure
the
mote
is
in
a
vertical,
upright
position
and
within
range
of
the
station.
d.
Repeat
these
steps
to
add
other
motes.
Press
the
Search
button
on
the
station
when
finished
adding
motes.
6.
Configure
the
station
in
HOBOlink.
In
HOBOlink,
click
Devices,
then
RX
Devices
and
click
the
icon
next
to
your
station.
Use
the
configuration
screens
in
HOBOlink
to
finish
setting
up
the
station,
starting
with
General
Configuration
(the
nickname,
time
zone,
and
image
for
the
station).
Use
the
Next
button
to
move
from
one
configuration
screen
to
the
next
or
use
the
left
menu
to
select
a
specific
item
to
configure.
Follow
the
steps
in
the
next
subsections
to
configure
the
readout
settings,
smart
sensors
(if
applicable),
and
wireless
sensors.
Note:
Click
Save
or
Next
in
any
screen
to
save
your
changes.
You
will
lose
any
changes
made
if
you
click
Back
without
clicking
Next
or
Save
first.
Readout
Configuration
a.
Click
Readout
from
the
Configuration
menu.
b.
Set
the
connection
interval,
which
is
how
often
the
station
will
connect
to
HOBOlink.
The
minimum
connection
interval
depends
on
your
communication
plan.
c.
If
you
wish
to
set
up
a
second
connection
interval,
select
the
“Night
mode”
checkbox.
Select
when
night
mode
should
begin
and
end
and
then
enter
the
connection
interval
you
want
to
use
during
that
part
of
the
day.
(The
night
mode
schedule
can
take
effect
any
time
during
the
day;
it
does
not
have
to
be
at
night.)
Use
this
option
to
save
data
in
your
communications
plan
(if
applicable)
or
to
conserve
battery
power
at
night
when
solar
charging
is
unavailable.
You
can
view
current
plan
usage
in
the
Device
Information
section
on
your
station’s
page
in
HOBOlink.
d.
Click
Save
or
click
Next.
Smart
Sensors
Logging
and
Configuration
You
can
configure
both
the
global
settings
that
affect
all
smart
sensors
(logging
interval
and
sampling
interval)
and
the
settings
for
each
smart
sensor
(labels,
graphs,
and
scaling).
a.
Click
Smart
Sensors
Logging
from
the
Configuration
menu.
b.
Select
the
logging
interval.
This
will
be
used
by
all
configured
smart
sensors.
c.
Enable
the
sampling
interval
and
enter
the
rate
to
use
in
minutes
and
seconds.
Or,
you
can
choose
a
specific
item
to
configure
from
this
menu
Use
the
Next
button
to
save
changes
and
move
through
each
configuration
screen
This
signal
strength
icon
blinks
while
searching
for
a
network.
Once
a
network
is
found,
the
icon
will
stop
flashing
and
the
bars
will
cycle
from
left
to
right.
iii.
iv.
This
network
connection
“x”
icon
blinks
while
the
mote
completes
the
registration
process,
which
may
take
up
to
five
minutes.
Once
the
mote
has
finished
joining
the
network,
the
“x”
icon
is
removed
and
the
channel
count
on
the
station
LCD
increases
by
the
number
of
measurement
channels
for
the
mote
plus
the
battery.
i.
ii.
Press
this
button
on
the
mote
for
3
seconds