background image

 

HOBO Temp Data Logger (UX100-001) Manual 

 

 

1-800-LOGGERS (564-4377) • 508-759-9500 

www.onsetcomp.com • loggerhelp@onsetcomp.com 

© 2013–2015 Onset Computer Corporation. All rights reserved. Onset, HOBO, and HOBOware are 
trademarks or registered trademarks of Onset Computer Corporation. All other trademarks are the 
property of their respective companies. 

16208-G 

 

2.

 

Remove the old battery from the tray. 

3.

 

Place the new battery in the tray with the positive side 
facing down. 

 

4.

 

With the LCD screen still facing up, slide the tray back into 
the logger. The LCD should display “HOBO” briefly after 
correctly installing the battery. 

 

WARNING:

 Do not cut open, incinerate, heat above 85°C 

(185°F), or recharge the lithium battery. The battery may 
explode if the logger is exposed to extreme heat or conditions 
that could damage or destroy the battery case. Do not dispose 
of the logger or battery in fire. Do not expose the contents of 
the battery to water. Dispose of the battery according to local 
regulations for lithium batteries. 

HOBOware provides the option of recording the current battery 
voltage at each logging interval, which is disabled by default. 
Recording battery life at each logging interval takes up memory 
and therefore reduces logging duration. It is recommended you 
only record battery voltage for diagnostic purposes. 

CR2032 battery being 
placed in the tray, 
positive side facing 
down 

Summary of Contents for HOBO UX100-001

Page 1: ...specification Logging Rate 1 second to 18 hours 12 minutes 15 seconds Logging Modes Fixed interval normal burst or statistics Memory Modes Wrap when full or stop when full Start Modes Immediate push button date time or next interval Stop Modes When memory full push button or date time Restart Mode Push button Time Accuracy 1 minute per month at 25 C 77 F see Plot B Power Source One 3V CR2032 lithi...

Page 2: ...ill continue recording data indefinitely with newest data overwriting the oldest data When first launched all five segments in the memory bar will be empty In this example the memory is full all five segments are filled in and new data is now overwriting the oldest data This will continue until the logger is stopped or the battery runs out The logger is currently logging A sensor reading is above ...

Page 3: ...ode data will always be recorded at the regular logging interval set in the previous step This is the default setting Burst In Burst mode logging will occur at a different interval when a specified condition is met See Burst Logging for more information Statistics In Statistics mode maximum minimum average and standard deviation statistics are calculated for the temperature during logging sampling...

Page 4: ... again in the afternoon If Consecutive is selected then an alarm will trip only if all sensor readings are 85 F or above for a continuous 30 minute period 6 Choose how long the logger should maintain the sensor alarm once it has tripped Select Host has relaunched logger if you want the alarm to remain visible on the LCD until the next time you relaunch the logger Select Sensor reading within limit...

Page 5: ...lution Once the high or low condition clears the logging interval time will be calculated using the last recorded data point in burst logging mode not the last data point recorded in normal mode For example let s assume the logger has a 10 minute logging interval and logged a data point at 9 05 Then the high limit was surpassed and burst logging began at 9 06 Burst logging then continued until 9 1...

Page 6: ...dropped below 2 5 V the logger performs a safe shutdown Mounting the Logger There are several ways to mount the logger using the materials included Use the four built in magnets on the back of the logger to mount it to a magnetic surface Attach the Command strip to the back of the logger to mount it a wall or other flat surface Use the double sided tape to affix the logger to a surface Insert the ...

Page 7: ...y installing the battery WARNING Do not cut open incinerate heat above 85 C 185 F or recharge the lithium battery The battery may explode if the logger is exposed to extreme heat or conditions that could damage or destroy the battery case Do not dispose of the logger or battery in fire Do not expose the contents of the battery to water Dispose of the battery according to local regulations for lith...