background image

HOBO® 4-Channel Pulse Input 
Data Logger (UX120-017x) Manual 

14638-E 

The HOBO 4-Channel Pulse Input data logger records electronic pulses and mechanical or 
electrical contact closures from external sensing devices. Using HOBOware®, you can easily 
configure each of its four channels to monitor and record pulse, event, state, or runtime data in 
a wide variety of applications, including tracking building energy consumption, monitoring 
mechanical equipment, and recording water and gas flow rates. Plus, when combined with the 
E50B2 Energy & Power Meter (T-VER-E50B2), this logger provides extensive power and energy 
monitoring capabilities. There are two models of the HOBO 4-Channel Pulse Input data logger: 
the UX120-017 stores more than 500,000 measurements while the UX120-017M holds more 
than 4,000,000 measurements. 

Specifications 

Inputs 

External Contact Input 

Electronic solid state switch closure or logic driven digital signals to  
24 V 

Maximum Pulse Frequency 

120 Hz 

Maximum State, Event, 
Runtime Frequency 

1 Hz 

Bits 

4–32 bits depending on pulse rate and logging interval 

Maximum Pulses Per 
Interval 

7,863,960 (using maximum logging rate) 

Driven Logic Signal 

Input Low:

 

 0.4 V; Input High: 3 to 24 V 

Absolute Maximum Rating 

Maximum Voltage: 25 V DC 
Minimum Voltage: -0.3 V DC 

Solid State Switch Closure 

Input Low: < 10 K

; Input High: > 500 K

 

Internal Weak Pull-Up 

100 K

 

Input Impedance 

Solid state switch closure: 100 K

 pull up; Driven signal: 4.5 K

 

Minimum Pulse Width 

Contact closure duration: 500 uS; Driven logic signal: 100 uS 

Lockout Time 

0 to 1 second in 100 ms steps 

Edge Detection 

Falling edge, Schmitt Trigger buffer 

Preferred Switch State 

Normally open or Logic “1” state 

Logging 

Resolution 

Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event 

Logging Rate 

1 second to 18 hours, 12 minutes, 15 seconds 

Time Accuracy 

±1 minute per month at 25°C (77°F) (see Plot A on next page) 

Battery Life 

1 year, typical with logging intervals greater than 1 minute and 
normally open contacts 

Battery Type 

Two AA alkaline or lithium batteries 

Memory 

Memory 

UX120-017: 520,192 measurements (assumes 8-bit) 
UX120-017M: 4,124,672 measurements (assumes 8-bit) 

Download Type 

USB 2.0 interface 

Download Time 

30 seconds for UX120-017, 1.5 minutes for UX120-017M 

Physical 

Operating Range 

Logging: -40° to 70°C (-40° to 158°F); 0 to 95% RH (non-condensing) 
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification 

Weight 

149 g (5.26 oz) 

Size 

11.4 x 6.3 x 3.3 cm (4.5 x 2.5 x 1.3 inches) 

Environmental Rating 

IP50 

The CE Marking identifies this product as complying with all relevant 
directives in the European Union (EU). 

HOBO 4-Channel Pulse 
Input Data Logger 

Models: UX120-017 

UX120-017M 

Included Items: 

4 Mounting screws 

2 Magnets

Hook & loop tape

4 Terminal block connectors

Required Items: 

HOBOware Pro 3.2 or later

USB cable (included with 
software)

Accessories: 

Additional terminal blocks 
(A-UX120-TERM-BLOCK) 

Lithium batteries (HWSB-LI) 

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com 

Summary of Contents for HOBO UX120-017

Page 1: ...osure 100 KΩ pull up Driven signal 4 5 KΩ Minimum Pulse Width Contact closure duration 500 uS Driven logic signal 100 uS Lockout Time 0 to 1 second in 100 ms steps Edge Detection Falling edge Schmitt Trigger buffer Preferred Switch State Normally open or Logic 1 state Logging Resolution Pulse 1 pulse Runtime 1 second State and Event 1 State or Event Logging Rate 1 second to 18 hours 12 minutes 15 ...

Page 2: ...up the Logger and Reading Out the Logger Setting Up the Logger Use HOBOware Pro to set up the logger including selecting the start and stop logging options configuring the input channels for specific sensor types and entering scaling factors It may be helpful to set up the logger with a Delayed Start or a Button Start first and then bring it to the location where you will mount it to connect the e...

Page 3: ...ical contact closure bouncing For more information on setting lockout time see the HOBOware Help Determining Logging Duration for Event State Data The logger s storage capacity and logging duration varies depending on several factors including logging interval number of channels configured and the type of data being recorded This table estimates the logging duration based on recording event or sta...

Page 4: ...AQ section on onsetcomp com Battery Information The logger is shipped with two AA alkaline batteries You can also use 1 5 V AA lithium batteries when deploying the logger in cold environments Expected battery life varies based on the temperature where the logger is deployed and the frequency the logging interval and the rate of state changes and or events at which the logger is recording data A ne...

Reviews: