2
HOBO LCD Temp/RH User’s Manual
Thank you and congratulations on your purchase of the HOBO
®
LCD data logger
from Onset Computer Corporation. Please read this manual thoroughly before
operating your HOBO LCD logger. Refer to the BoxCar
®
Pro User’s Manual for
details on using the host PC software. If you are also using a Palm™ handheld and
HandCar
®
software, refer to the HandCar User’s Manual.
WARNING: The HOBO LCD Logger, Remote Alarm, and/or Autodialer are
not certified for and should not be deployed in any hazardous (classified)
location where ignitable concentrations of gas and/or dust exist.
IMPORTANT: The HOBO LCD Logger, Remote Alarm, and/or Autodialer are
not intended for and should not be used for medical or life support,
aerospace, or nuclear installation applications.
Software/Cable Requirements
The HOBO LCD logger requires Onset Computer Corporation’s BoxCar Pro
software version 4.3 or later and a PC interface cable for operation. For optional
operation with a Palm handheld, the HOBO LCD logger requires HandCar
software version 1.1 or later, and a Palm handheld interface cable.
Functional Overview
The HOBO LCD logger records time-stamped relative humidity (RH) and
temperature measurements in nonvolatile memory and also displays the current
temperature and RH on the LCD. Logging parameters are set from a host
computer running BoxCar Pro software. The logger is then started using the host
computer or a Palm handheld running HandCar software. The logger updates
displayed measurements every five seconds. The sample (logging) interval is
software-selectable from one second to nine hours. Data in the LCD logger can be
offloaded to a host computer or Palm handheld.
Additional Features
•
ALERT indicator signals when temperature or relative humidity limits have
been exceeded (software-selectable using BoxCar Pro).
•
Contact closure connections for optional remote audio alarm and/or
autodialer. Triggers on ALERT conditions.
•
Memory Left (MEM LEFT) indicator on LCD shows how much data storage
space remains.
•
Battery Level (BATT LEVEL) indicator on LCD shows how much useful
battery life remains.
•
Software-selectable Fahrenheit or Celsius temperature units.
•
Internal relative humidity measurement range of 15% to 95%.
•
Internal temperature measurement range of -20°C to +50°C (-4°F to +122°F).
•
External probe model with choice of temperature and temperature/RH probes
(see specifications on page 13).
•
Operates for one year on three alkaline AAA batteries in typical conditions.
HOBO LCD Temp/RH User’s Manual
15
product(s), properly packaged to protect against further damage, to Onset (at your
expense) with the RMA number marked clearly on the outside of the package.
Onset is not responsible for any package that is returned without a valid RMA
number or for the loss of the package by any shipping company. Products must be
clean and free of any toxins before they are sent back to Onset or they may be
returned to you.
Repair Policy
Products that are returned after the warranty period or that are damaged by the
customer as specified in the warranty provisions can be returned to Onset with a
valid RMA number for evaluation.
Optional Services
Please contact Onset for more information and prices on:
•
ASAP Repair.
Onset will expedite the repair of a returned product.
•
Data-back™ Service.
HOBO data loggers store data in nonvolatile
EEPROM memory. Onset will, if possible, recover your data to a disk.
•
Tune Up Service.
Onset will examine and retest any HOBO data logger.
Warranty
Onset Computer Corporation (“Onset”) warrants to the original end-user purchaser for a
period of one year from the date of original purchase that the HOBO
®
product(s) purchased
will be free from defect in material and workmanship. During the warranty period Onset
will, at its option, either repair or replace products that prove to be defective in material or
workmanship. This warranty shall terminate and be of no further effect at the time the
product is (1) damaged by extraneous cause such as fire, water, lightning, etc. or not
maintained in accordance with the accompanying documentation; (2) modified; (3)
improperly installed; (4) repaired by someone other than Onset; or (5) used in a manner or
purpose for which the product was not intended.
Disclaimer and Limitation of Liability
ONSET’S OBLIGATION UNDER THIS WARRANTY IS LIMITED TO REPAIR OR
REPLACEMENT OF THE PRODUCT. ONSET SHALL HAVE NO LIABILITY FOR
ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM THE
USE OF THE HOBO
®
PRODUCT(S) EVEN IF ONSET KNEW OR SHOULD HAVE
KNOWN OF THE POSSIBILITY OF SUCH DAMAGES.
Onset shall not be liable for injury to persons or property resulting from the use of HOBO
®
product(s) or the failure of such product(s). Onset’s liability, if any, shall be limited to the
original purchase price paid for the product. Onset assumes no liability for installation of
the product(s) and/or interruptions of service due to strikes, riots, floods, fire, and/or any
cause beyond Onset’s control.
Legal Remedies
This warranty gives you specific legal rights. You may also have other rights which vary by
jurisdiction. The remedies provided herein are in lieu of all other remedies, express or
implied.