InTempConnect Users 

Only InTempConnect users belonging to the same 
InTempConnect account can connect to a logger once it is 
configured. When an InTempConnect user first configures a 
logger, it is locked with an encrypted passkey that is 
automatically generated by the InTemp app. After the logger is 
configured, only active users associated with that account will 
be able to connect to it. If a user belongs to a different account, 
that user will not be able to connect to the logger with the 
InTemp app, which will display an invalid passkey message. 
Administrators or users with the required privileges can also 
view the passkey from the device configuration page in 
InTempConnect and share them if needed. See 
www.intempconnect.com/help for more details. 

Note:

 This 

does not apply to InTempVerify. if the logger was configured 
with a logger profile in which InTempVerify was enabled, then 
anyone can download the logger with the InTempVerify app. 

InTemp App Only Users 

If you are using the InTemp app only (not logging in as an 
InTempConnect user), you can create an encrypted passkey for 
the logger that will be required if another phone or tablet 
attempts to connect to it. This is recommended to ensure that 
a deployed logger is not mistakenly stopped or purposely 
altered by others. 

To set a passkey: 

1.

 

Tap the Devices icon and connect to the logger. 

2.

 

Tap Set Logger Passkey. 

3.

 

Type a passkey up to 10 characters. 

4.

 

Tap Save. 

5.

 

Tap Disconnect. 

Only the phone or tablet used to set the passkey can then 
connect to the logger without entering a passkey; all other 
mobile devices will be required to enter the passkey. For 
example, if you set the passkey for the logger with your tablet 
and then try to connect to the device later with your phone, 
you will be required to enter the passkey on the phone but not 
with your tablet. Similarly, if others attempt to connect to the 
logger with different devices, then they would also be required 
to enter the passkey. To reset a passkey, simultaneously press 
both the top and bottom button on the logger for 5 seconds, or 
connect to the logger, tap Set Logger Passkey, and select Reset 
Passkey to Factory Default. 

Downloading the Logger 

You can download the logger to a phone or tablet and generate 
reports that include logged probe (if applicable) and ambient 
readings, events, user activity, alarm information, and more. 
Reports can be shared immediately upon download or accessed 
later in the InTemp app.  

InTempConnect users:

 Privileges are required to download, 

preview, and share reports in the InTemp app. Report data is 
automatically uploaded to InTempConnect when you download 
the logger. Log in to InTempConnect to build custom reports 
(requires privileges). In addition, InTempConnect users can also 
download CX loggers automatically on a regular basis using the 
CX5000 Gateway. Or, if the logger was configured with a logger 
profile in which InTempVerify was enabled, then anyone can 

download the logger with the InTempVerify app. For details on 
the gateway and InTempVerify, see www.intempconnect/help. 

To download the logger with the InTemp app: 

1.

 

Tap the Devices icon and connect to the logger. 

2.

 

Tap Download. 

3.

 

Choose a download option: 

 

Download & Continue. The logger will continue logging 
once the download is complete. 

 

Download & Restart. The logger will start a new data set 
using the same profile once the download is complete. 

 

Download & Stop. The logger will stop logging once the 
download is complete. 

To download multiple loggers with the InTemp app: 

1.

 

Tap Devices, then Bulk Download. 

2.

 

The screen changes to Bulk Download mode. This changes 
the way the screen behaves when you tap on a logger tile. 
Tap on a tile to select it for bulk download. You can select 
up to 20 loggers. Text at the bottom of the page updates to 
indicate how many loggers are selected. 

3.

 

Tap Download X Loggers to begin the download.  

 

Download & Continue. The loggers continue logging 
once the download is complete. 

 

Download & Restart (CX400, CX450, CX503, CX603, and 
CX703 models only). The logger starts a new 
configuration using the same profile once the download 
is complete. You will be prompted to enter trip 
information again (if applicable). Note that if the logger 
profile is set up to start with a button push, you must 
push the button on the logger for logging to restart. 

 

Download & Stop. The logger stops logging once the 
download is complete. The downloads begin and run 
one after another. The screen displays the download 
queue. 

4.

 

Click Cancel to cancel the downloads and return to the 
Devices screen, not in Bulk Download mode. 

5.

 

The screen displays Done when all the loggers are 
downloaded. 

A report of the download is generated and is also uploaded to 
InTempConnect if you are logged into the InTemp app with 
your InTempConnect user credentials. If you are using the bulk 
download feature, one report per logger is generated. 

In the app, tap Settings to change the default report type and 
report sharing options. The report is also available in Secure 
PDF, XLSX, and VFC CSV (if enabled) formats for sharing later. 
Tap the Reports icon to access previously downloaded reports. 
See www.intempconnect.com/help for details on working with 
reports in both the InTemp app and InTempConnect. 

Performing Logger Checks 

If your monitoring application requires that you perform daily 
or twice daily checks of the logger, you can use the InTemp app 
to connect to the logger and perform a check. 

To enable the perform check feature in the InTemp app (if you 
are not using InTempConnect): 

1.

 

Tap the Settings icon. 

Summary of Contents for InTemp CX402-T205

Page 1: ...o 212 F Resolution 0 024 C at 25 C 0 04 F at 77 F Drift 0 1 C 0 18 F per year NIST Calibration CX40x Txx and CX402 BxM Single point NIST calibration probe and logger body CX40x VFCxxx Single point NIS...

Page 2: ...or measures ambient temperature External Temperature Probe This is the probe that is plugged into the logger for measuring temperature CX402 models only Audible Alarm Speaker This is the speaker for t...

Page 3: ...oftware where you can monitor CX400 series logger configurations and view downloaded data online Using the InTemp app you can configure the logger with your phone or tablet and then download reports w...

Page 4: ...nimum and maximum readings represent the entire logging period and only reset when the logger is downloaded and restarted or stopped and reconfigured they will not reset if you download the logger and...

Page 5: ...empConnect when you download the logger Log in to InTempConnect to build custom reports requires privileges In addition InTempConnect users can also download CX loggers automatically on a regular basi...

Page 6: ...h this reset Logger Events The logger records the following events to track logger operation and status These events are listed in reports downloaded from the logger Event Name Definition Started The...

Page 7: ...ts in extremely cold or hot temperatures or a logging interval faster than 1 minute can impact battery life Estimates are not guaranteed due to uncertainties in initial battery conditions and operatin...

Page 8: ...o radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception wh...

Reviews: