background image

-25- 

external temperature sensor, if connected. If not connected 

-- 

will be written instead. 
If there is an asterisk, for example 

*24,2 

before the number 

this indicates that the unit has sent a temperature trigged by 
this sensor. 

Tstat: 25 

Indicates the set temperature for the thermostat function. If 
thermostat not is activated the message is 

Tstat: OFF

.

 

SMS about power supply 

The SMS sent to alert about the power supply are as follows 
 

Content in SMS 

Meaning 

Charge battery! 

Is sent when voltage is dropping below 12 
Volt 

Battery empty! 

Is sent when voltage is dropping below 11 
Volt 

SMS showing the SIM card settings 

If you want to control the settings of the SIM card you can request an SMS that shows 
most of the SIM card settings. Send an SMS to the unit with the following content: 

ABCD#8*2# 

where ABCD is your personal PINCODE. 

You will immediately receive an SMS as below: 
 

Content 

Exlanation 

*Ontech 9030 

Asterisk (

*

) means alarm function is turned on 

Alarmrelay: 

Alarmrelay function; 

ON

 or 

OFF

 

Tempwatch: 

<

 indicates if the unit alarms when the temperature drops 

below

 set temperature. 

>

 indicates if the unit alarms when the temperature rises 

above

 set temperature. 

Temp sens: 

Indicates which temperature sensor that controls alarms 
and thermostat; 

 INT

=internal sensor, 

EXT

=den external 

sensor. 

Ver 

Shows software version. Useful when contacting support. 

Summary of Contents for GSM 9030

Page 1: ...Ontech GSM 9030 Users Manual aENGLISHa...

Page 2: ...1234 1 0 Also the buttons to be pressed when using a telephone in tone mode not pulse is shown in this way Text in italic indicates a menu in your mobile phone for example Contacts Quotation mark shal...

Page 3: ...after a power failure 11 Alarm 11 Wired alarm 12 Wireless alarm detectors 13 Delayed activation of alarm detector 14 Activation of relay when alarming Alarmrelay 14 Turn off on the alarm function 14...

Page 4: ...4 Commands 26 Push button 27 The lamps 27 The DIP switch 28 Tip 29 Troubble shooting 31 Technical specifications 32 Declaration of conformity 33 Declaration of conformity 33...

Page 5: ...MS Relay230V 16A Has a timer function Can be programmed to remember position after a power failure Two alarm inputs for corded alarm detectors Can be set to NO or NC Can be programmed to activate rela...

Page 6: ...mobile phones menu a Create a new entry Name it PINCODE b In the field for telephone number enter your personal four digit number This number is the PINCODE you must enter each time you contact your O...

Page 7: ...ble to set a delayed activation for an alarm detector This is for giving you time to deactivate the alarm before the unit is sending an alarm 2 Create a new contact Name it DELAYX X is the ID of the a...

Page 8: ...nal temp sensor optional and you want it to control the temperature alarm and thermostat you have to activate it Create a new contact and name it EXTTEMP i In the telephone number field write 1 5 Acti...

Page 9: ...The green lamp starts flashing for about 45 seconds This indicates that the unit is searching an GSM network b Finally the green lamp is lit The unit is communicating with the GSM network and the unit...

Page 10: ...the PINCODE is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 4 Activate the relay by pressing the buttons as follows 1 1 The unit confirms with...

Page 11: ...use all letters uppercase or lowercase on button 9 w x y or z Tip If you not are sure about the settings of the unit you can request a SIM card setting SMS see page 25 The position of the relay after...

Page 12: ...an alarm detector is activated it will either close or open an electric circuit It can be a magnetic switch detector a level detector a motion detector or any other kind of sensor The jacket on the u...

Page 13: ...rmally Closed NC mode Wireless alarm detectors Ondico AB will market wireless alarm detectors These can be easily connected to work together with Ontech GSM 9030 Up to 7 different detectors can be con...

Page 14: ...evel is too high the relay is activated and turns on a pump The function is activated by adding a contact on the SIM card and name it ALARMRELAY In the telephone number field write 1 see page 8 The fu...

Page 15: ...ondico se Tip If you want to know if the alarm is turned on or off you can check this by requesting a status SMS from the unit see page 25 When the alarm is turned on there is an asterisk before the n...

Page 16: ...r refers to external temperature sensor if connected If not connected will be written instead If there is an asterisk for example 24 2 before the number this indicates that the unit has sent a tempera...

Page 17: ...you wish higher accuracy 1 we recommend you to purchase the external temperature sensor Ontech Temp Sensor 9020_002 Installation of external temperature sensor The external temperature sensor is conne...

Page 18: ...m set alarm temperature If the alarm is set to alarm when it drops below temperature X it will not send another alarm before it has risen above X 1 degrees If the alarm is set to alarm when it rises a...

Page 19: ...PINCODE and then Example 1234 If the PINCODE is correct the unit replies with a beep If it is not correct the call is disconnected Call again and try 4 Dial 2 D where D the desired temperature The un...

Page 20: ...20 Deactivate the thermostat with SMS 1 Deactivate the thermostat function by sending an SMS with the following content ABCD 2 where ABCD is your personal PINCODE...

Page 21: ...y not be used Decrease power consumption In order to decrease power consumption you can turn off the short range radio if it not is used The power consumption will then decrease with about 10 mA The s...

Page 22: ...22 Important If there has been a low battery alarm the unit has to be restarted or the voltage must rise above 12 5 V before it can send a new low battery alarm...

Page 23: ...ge 21 In a system with one Ontech GSM 9030 and one or more extra relays or wireless alarm detectors all has individual ID numbers Up to 8 different unique numbers can be used 1 8 Ontech GSM has always...

Page 24: ...tech 9030 is always no 1 and the others refer to the extra units ore wireless alarm detectors connected Note that these inputs not can send an alarm again before the alarm has been acknowledged Inputs...

Page 25: ...11 Volt SMS showing the SIM card settings If you want to control the settings of the SIM card you can request an SMS that shows most of the SIM card settings Send an SMS to the unit with the followin...

Page 26: ...e relay to be active 2 Used to turn off the thermostat function 2 D Used to turn on the thermostat function 0 29 degrees C 7 1 Used to turn on the alarm function 7 0 Used to turn off all alarms valid...

Page 27: ...amps On the front of the cabinet there are two lamps one red and one green GREEN LAMP Flashing Flashes when establishing connection with GSM network during start up On no flashing The unit is turned o...

Page 28: ...t the radio channel If extra relays Ontech Relay 9010 or wireless alarms are used in a system all units must have the same radio channel settings 3 4 5 6 OFF Short range radio turned on ON Short range...

Page 29: ...other letters for and Instead of the symbol you can use all letters uppercase or lowercase on button 7 p q r or s Instead of the symbol you can use all letters uppercase or lowercase on button 9 w x...

Page 30: ...One push of the button on the extra unit Ontech Relay 9010 switches the relay but is also sending information about this to Ontech GSM 9030 This unit acknowledges back that it has received the informa...

Page 31: ...ra units or wireless alarms Different radio channels Check so all units in a system has the same radio channel See page 23 Ontech GSM 9030 has no contact with an individual extra unit Out of radio ran...

Page 32: ...al interface Special for GPS adapter Short range radio Frequency 2 4 GHz Power output 1 mW Alarm inputs Activated either by NO or NC mode Maxi 50 V 5 mA External power supply 9 24 V AC DC Power consum...

Page 33: ...claration of conformity Ondico AB Datav gen 14A 436 32 Askim Sweden hereby declares that the product Ontech GSM 9030 is in conformity with the provisions of the Radio Teleterminal directive R TTE 1999...

Page 34: ...34...

Page 35: ...35...

Page 36: ...36 www ondico se 15050_IB_EN_100820...

Reviews: