background image

 

 

 

 

 

 

 

pic1                                                pic2 

 

When  the  suction  arm  is  not  placed  on  the  record,  open  the  water  suction 

switch. The pointer of the barometer points to -0.02~-0.04. If the barometer is 

less than 0.02, the sewage bottle may not be tightened. 

pic1

 

 

When the suction arm is placed on the record to start working, the pointer of 

the barometer points in the range of -0.05~-0.07. If the barometer is larger than 

-0.07, the suction hole may be blocked. Lift the suction arm and then lower it to 

solve.

pic2

 

 

Note: The air pressure will increase when the suction head reaches the 

edge of the record. Adjusting the front and rear position of the weight of 

the suction arm can finely adjust the water pressure. 

 

2. 

Check the water in the sewage bottle regularly. If it exceeds half a bottle, 

pour it off and cut off the cleaning line. Install the bottle. Please gently align the 

cover and tighten it counterclockwise. 

unplug the power cable. 

3. The sewage bottle needs to be squared and carefully rotated to the marked 

position, otherwise it will leak. 

4. There is  a clean  water drop when cleaning the disc,  and a special plastic 

tray can be purchased to prevent clean water from flowing into the surface of 

the main unit. 

 

 

Specifications

 

Use voltage: 220~230V 50Hz 

Rated power: 300W 

Dimension: 400x320x330mm

WxDxH

 

 

 