Biopel line
– RT10 room regulator
13
After pressing this icon a panel will be displayed where you can set a threshold temperature for the
room - if the temperature in the room drops below this set-point value the furnace will be turned on
irrespective of your time schedule settings.
▪ Temp in room disabled:
After pressing this icon a panel will be displayed where you can set a threshold temperature for the
room - if the temperature in the room rises above this set-point value the furnace will be turned off
irrespective of your time schedule settings.
1.2.6 Language selection
Press the Language selection icon in the main menu to access the user language selection panel.
1.2.7 About the program
Press this icon to display the logo of the furnace manufacturer and the version of the software.
1.2.8 Settings
Press this icon to change additional parameters.
➢
Sensor
– after pressing this icon a panel will be displayed that allows you to change the hysteresis
and calibration settings of the temperature sensor of the room thermostat.
Sensor calibration. The sensor is calibrated during installation or after prolonged use of the thermostat,
if the room temperature as measured by the internal sensor deviates from the actual one.
Adjustment range: between -10 and +10
°C with an accuracy of 0.1°C.