Biopel line
– RT10 room regulator
15
2 ALARMS AND TECH SPECIFICATION
The RT10 room temperature thermostat will indicate all alarms going off in the main controller of the
central heating furnace. When an alarm is activated the room thermostat will sound a beep and the
display will show the same message as that on the furnace controller. If the internal sensor suffers
damage an alarm will be displayed saying
”Room temperature sensor demaged”.
Technical specifications:
Setting range for room temperature 5oC - 40oC
Power supply voltage 5V / DC
Power consumption 1.3W
Room temperature measurement error +/- 0.1OC
Operating temperature 5oC - 50oC