Description optek Control 4000 / Haze Control bus interface
- 15 -
optek-Manual--1004-1010-02--ProfibusPA-US-2017-06-23
5.3
Rear view converter C4151
Fig. 5
Rear view converter C4151
Numbers stand for:
1. Detector input A (only for optek-sensors)
2. -
3. PROFIBUS
®
PA interface
4. mA-output 1, mA-output 2 (0/4–20 mA)
5. -
6. Lamp output E (only for optek-sensors)
7. -
8. Relay outputs 1, 2, 3 for limit values or system status feedback, system relay
(enabled)
9. -
10. Fuse I 115/230 V AC T 1.6 A (option 24 V AC/DC: T 3.15 A)
11. Fuse II 115/230 V AC T 1.6 A (option 24 V AC/DC: T 3.15 A)
12. Power supply (fixed)
13. Selector switch for voltage (preset 230 V AC) -
(does not apply for a 24 V AC/DC version)
14. Equipotential bonding (in the non-ex-proof version, only necessary in
extreme EMC requirements)
15. ON / OFF switch
16. -
17. Detector input C (inactive)
19
20
21
V DC
6
230V
DETECTOR INPUTS
[C]
3
4
5
3
4
5
[D]
OPTEK - DANULAT
M6
PA
L
PE
N
R6
R8
RR
R7
R2
R5
R4
R3
R1
MADE IN GERMANY
36
39
37
38
32
34
35
33
31
15
18
16
17
11
13
14
12
10
6
7
6
7
LAMP [F]
7
7
6
V DC
acc. to
length
cable
acc. to
cable
length
DETECTOR INPUTS
[A]
5
2
1
[B]
5
2
1
REMOTE IN
115 / 230 V, 50 / 60 Hz, 50 VA
115 / 230 V, T 1,6 A
!
24 V DC
0 / 4 - 20 mA
OUT 1, 2
RELAY OUT
24 V AC / DC
51
53
54
52
40
42
43
41
46
47
45
44
LAMP [E]
OUT 3, 4
1
4
6
8
10
11
12
13
14
15
17
3