background image

BEF-BE01-W190 (2 pcs)

End Unit

D2RF-TA

(Unit: mm)

Maximum
aperture 150

Backside of bracket

Website

http://www.optex-fa.com

 0537450

     Specifications and equipment are subject to change

 

     without any obligations on the part of manufacture

r.

     For more information, questions and comments 

     regarding products, please contact us below

.

Head office: Mitsui Seimei Kyoto Yamashina BLDG 6F,  46-1

 

Takehanadounomae-cho, Yamashina-ku, Kyoto

 607-8085 

Japan

 TEL: 

+81-(0)75-594-8123

 FAX: 

+81-(0)75-594-8124

Manufactured and sold by :

16.3

55.4

18.8

27.8

34.8

5.6

7

4.3

10

68.9

2.6

3

14

33.4

10.5

32

7.8

9.4

8

O 7.6

2- O 2.2

2- R2.1

n4.2

9

3

2-R1.6

2-R1.6

9.5

8

Dimensional drawing

Options

Input / Output Connection

NPN

PNP

output 

Circuit

Analog
Output

Main circuit

12~24V DC

Blue

Black

Brown

Load

Protection

Control

0V

White - Black

Optex-FA U.S. sales
Ramco Innovations
(800) 280-6933
www.optex-ramco.com

Analog Gnd

output 

Circuit

Analog
Output

Main circuit

12~24V DC

Blue

Black

Brown

Protection

Control

0V

White - Black

Analog Gnd

Load

o

Summary of Contents for D2RF Series

Page 1: ...el Analog Output Cable type D2RF TA N P Power source voltage 12 24V DC 10 including ripple Consumption current 45mA or less 24V When not using analog output Response time 60 s 250 s 2 ms Fast Standard Long Control output NPN PNP Open collector 100mA 30V or less Load current 100mA or less Residual voltage 1 8V or less Output method Selectable Light on Dark on Short circuit protection Incorporated L...

Page 2: ...n the background without the object present Switch to RUN Select Two point teaching Auto Teaching SET RUN Switch to SET SET RUN Switch to RUN Select Auto teaching End Press the teaching button Start Press the teaching button The threshold flashes and the display returns to normal T T Thru beam Reflective type Start and end Perform the adjustment with objects passing by the sensor Zone Teaching SET...

Page 3: ...turn to the normal display T Function Setting TOP Select a display method of normal main sub monitor Select by using and set with Displayed in bar display Displayed in numeric display Displayed in percent display No display A 5 2 Display setting TOP Set the displayed value on the main monitor to 0 Select by using and set with Turn on Zero reset Turn off Zero reset 5 1 Zero reset setting TOP Select...

Page 4: ...o prevent accidental operation Hold down both of the buttons for more than 2 seconds in the RUN mode to activate the Key Lock function Repeat this procedure to cancel the Key Lock Locked Unlocked Optex FA U S sales Ramco Innovations 800 280 6933 www optex ramco com Span setting is for span change is for digit change and is to set The screen returns to the TOP of Span setting TOP Set the span of th...

Page 5: ...amashina ku Kyoto 607 8085 Japan TEL 81 0 75 594 8123 FAX 81 0 75 594 8124 Manufactured and sold by 16 3 55 4 18 8 27 8 34 8 5 6 7 4 3 10 68 9 2 6 3 14 33 4 10 5 32 7 8 9 4 8 O 7 6 2 O 2 2 2 R2 1 n4 2 9 3 2 R1 6 2 R1 6 9 5 8 Dimensional drawing Options Input Output Connection NPN PNP output Circuit Analog Output Main circuit 12 24V DC Blue Black Brown Load Protection Control 0V White Black Optex F...