Australian Standard Input Pump Power for Independent Systems
Pool
Water
Volume
Min - Max
Recommended
Flow
For 1
st
Story Install (3m):
For 2
nd
Story Install (6m):
Min - Max
Input Pump Watts
Min - Max
Input Pump Watts
20,000 L
50 - 67 L/min
270 - 300 Watts
350 - 380 Watts
25,000 L
63 - 83 L/min
300 - 330 Watts
370 - 410 Watts
30,000 L
75 - 100 L/min
320 - 370 Watts
400 - 450 Watts
35,000 L
88 - 117 L/min
340 - 400 Watts
420 - 480 Watts
40,000 L
100 - 133 L/min
360 - 440 Watts
450 - 520 Watts
45,000 L
113 - 150 L/min
390 - 470 Watts
470 - 560 Watts
50,000 L
125 - 167 L/min
420 - 510 Watts
500 - 600 Watts
55,000 L
138 - 183 L/min
450 - 560 Watts
530 - 640 Watts
60,000 L
150 - 200 L/min
470 - 600 Watts
560 - 690 Watts
65,000 L
163 - 217 L/min
500 - 640 Watts
600 - 740 Watts
70,000 L
175 - 233 L/min
530 - 700 Watts
620 - 790 Watts
75,000 L
188 - 250 L/min
570 - 740 Watts
660 - 840 Watts
80,000 L
200 - 267 L/min
600 - 790 Watts
700 - 900 Watts
If you don’t know your pools water volume you can look it up from the table supplied below based on the total
water area and average depth:
7.2
Solar Pump Sizing for Booster Systems
Pool Water area vs Average Depth Conversion Table
Average depth
Waters Area 1.3 m
1.4 m
1.45 m
1.5 m
1.55 m
1.6 m
1.65 m
1.7 m
1.8 m
10 m
2
13000 L 14000 L 14500 L 15000 L 15500 L 16000 L 16500 L 17000 L 18000 L
15 m
2
19500 L 21000 L 21750 L 22500 L 23250 L 24000 L 24750 L 25500 L 27000 L
20 m
2
26000 L 28000 L 29000 L 30000 L 31000 L 32000 L 33000 L 34000 L 36000 L
25 m
2
32500 L 35000 L 36250 L 37500 L 38750 L 40000 L 41250 L 42500 L 45000L
30 m
2
39000 L 42000 L 43500 L 45000 L 46500 L 48000 L 49500 L 51000 L 54000 L
35 m
2
45500 L 49000 L 50750 L 52500 L 54250 L 56000 L 57750 L 59500 L 63000 L
40 m
2
52000 L 56000 L 58000 L 60000 L 62000 L 64000 L 66000 L 68000 L 72000 L
45 m
2
58500 L 63000 L 65250 L 67500 L 69750 L 72000 L 74250 L 76500 L 81000 L
50 m
2
65000 L 70000 L 72500 L 75000 L 77500 L 80000 L 82500 L 85000 L 90000 L
55 m
2
71500 L 77000 L 79750 L 82500 L 85250 L 88000 L 90750 L 93500 L 99000 L
For booster type systems
you should choose a pump at or just below the minimum
specs in the table above.
Why?
The take off point for solar is already pressurized by the
filter pump, hence a smaller pump should be used.