Wiring
Wire the OC-907C T.
CAUTION
CAUTION
Do not turn the power on while wiring. Otherwise, electric shock or device damage may result.
OC-907C T
Power harness × 1 and door controller interface × 2 (for double door left and right sides) are included.
• Power harness
36”
(920 mm)
Name
Color
Specifications
1.
Power (*1)
Orange
12 to 30 VDC
2.
Power (*1)
Brown
*1: No polarity.
• I/O harness
I/O harness × 2
(for double door left and right sides)
4’3’’
(1300 mm)
Name
Color
I/O
Specifications
1.
Activation output
Yellow
Output
Form A relay 50 V, 0.3 A (resistance load)
At power OFF: Open
At stand-by: Open, at detection: Close
2.
Activation output
Yellow
Output
3.
None
-
-
-
4.
None
-
-
5.
Stall output
Green
Output
Form A or B relay 50 V, 0.3 A (resistance load)
Set form A or B with the setting app.
When setting N.O.
At power OFF: Close
At stand-by: Open
At detection: Close
When setting N.C.
At power OFF: Close
At stand-by: Close
At detection: Open
6.
Stall output
Green
Output
7.
Test input
Pink
Input
Optocoupler voltage 5 to 30 VDC, current 6 mA max. (30 VDC) (no polarity)
8.
Test input
Pink
Input
9.
BodyGuard input or
Motor voltage input
Red
Input
Optocoupler voltage 5 to 160 VDC, 5 to 120 VAC, 60 Hz (no polarity)
10. BodyGuard input or
Motor voltage input
Red
Input
11. None
-
-
-
12. None
-
-
13. Knowing act input
Purple
Input
Dry contact input
Connect push plate, etc.
14. Knowing act input
Purple
Input
15. Close switch input
White
Input
Dry contact input
Connect a device recognizing door fully closed status (a magnet switch, etc.).
16. Close switch input
White
Input