Detection area adjustment
The first row from the door (row in diagonal line) is called the threshold area and the 2nd and 3rd rows the swing area; the depth angle for each
can be set separately.
With the angle adjustment screws for the threshold and swing areas on the OA-607 T front, each area’s depth angle (angle seen from side) can
be independently adjusted between -5 and +5° (respectively SHALLOW and DEEP).
NOTE
NOTE
Recommended detection angle setting: +5°
CAUTION
CAUTION
Adjust the areas in accordance with ANSI 156.10.
-5°
+5°
0°
Threshold area
(1st row)
Swing area
(2nd,3rd row)
Side view
When both threshold
area and swing area are
+5°
When both threshold
area and swing area are
-5°
When both threshold
area and swing area are
0°
Sensor pattern
H
J
L
N
B
C
D
E
F
G
I
K
M
O
A
: Threshold area (1st row)
: Swing area (2nd/3rd row)
Value dimensions for each door angle
[feet (mm)]
Door angle Door fully closed
30° Open
45° Open
60° Open
Door fully opened
A
6’7” (2000)
7’6” (2300)
B
7” (186)
8” (214)
C
1’2” (360)
1’4” (414)
D
6” (152)
7” (175)
E
2’9” (840)
3’2” (966)
F
5’5” (1650)
6’2” (1898)
G
10” (252)
H
1’11” (593)
2’1” (645)
I
3” (89)
6” (141)
J
3’ (911)
3’4” (1010)
K
1’4” (407)
1’8” (506)
L
4’2” (1275)
4’8” (1428)
M
2’6” (770)
3’ (924)
N
5’6” (1684)
6’3” (1900)
O
3’10” (1180)
4’7” (1395)