The actual detection area may become smaller depending on the ambient light, the color / material of
the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
50mm / sec. or faster than 1500mm / sec.
NOTE
Mounting height : 2.2m(7'3")
Angle adjustment : +6°
Sensitivity : Middle
: Emitting spots
: Detection area
: Emitting spots
(can be eliminated)
Test conditions required by EN 16005
Floor :Grey paper
Detection object : EN 16005 CA reference body
Sensitivity : Middle
Speed of detection object : 50mm / sec.
To comply with EN 16005, make sure that the detection area is within the values of the chart below.
Detection area
The chart shows the values at depth angle +6°
Emitting area
A
X
E
G*
2.20 (7'3")
2.00 (6'7")
0.25 (10")
1.12 (3'8")
2.65 (8'8")
3.00 (9'10")
0.34 (1'1")
1.53 (5')
3.60 (11'10")
0.23 (9")
1.02 (3'4")
2.41 (7'11")
The values above are those of the
Detection area
when tested referring to the test conditions of EN 16005.
(The emitting area is as shown in
Emitting area
above.)
*: When installed at higher than 3.0m(9'10"), EN 16005 requirements are fulfilled only within the area width "G"
of 3.6m(11'10").
[m(feet,inch)]
A
E
F
G
0
1.0
(3′3")
1.0(3′3")
1.0
(3′3")
2.0
(6′7")
2.0
(6′7")
2nd row
B C
D
A
B
C
D
E
F
2.20 (7'3")
0.25 (10")
0.39 (1'3")
0.65 (2'2")
1.33 (4'4")
2.70 (8'10")
0.31 (1')
3.00 (9'10")
0.34 (1'1")
0.48(1'7")
0.80 (2'7")
0.53 (1'9")
0.89 (2'11")
1.63 (5'4")
1.81 (5'11")
2.50 (8'2")
0.28 (11")
0.44 (1'5")
0.74 (2'5")
1.51(4'11")
2.00 (6'7")
0.23 (9")
0.35 (1'2")
0.59 (1'11")
1.21 (3'12")
2.05 (6'9")
2.51 (8'3")
2.79 (9'2")
2.32 (7'7")
1.86 (6'1")
G
2.78 (9'1")
3.40 (11'2") 3.79 (12'5")
3.50 (11'6")
0.39 (1'3")
0.61 (2')
1.03(3'5")
2.11 (6'11")
3.25 (10'8")
4.42 (14'6")
3.15 (10'4")
2.52(8'3")
[m(feet,inch)]
X
Mounting
surface
1st row
OA-PRESENCE TN
DETECTION AREA