38(1 1/2")
61(2 3/8"
)
267(10 1/2")
125(4 15/16")
36(1 7/16")
43(1 11/16")
7.5(5/16"
)
MANUFACTURER'S STATEMENT
DETECTION AREA
OUTER DIMENSIONS AND PART NAMES
ENGLISH
ORIGINAL
5919151 MAR 2013
TM-0072-7
(1) Connector
(2) Mounting holes
(3) Operation indicator
(4) Width adjustment screws
(5) Depth angle adjustment screw
(6) Function switch
(7) Microwave sensitivity potentiometer
(8) Dipswitches
(9) Detection window
(10) Area adjustment tool
Model
Cover color
Mounting height
Detection area
Detection method
Depth angle
adjustment
Power supply *2
Power consumption
Operation indicator
Test input
Activation output
: OAM-DUAL T / TV / TF / TT
: Black
: 2.0 (6'6") to 3.5m (11'6")
: See
DETECTION AREA
: Active infrared reflection *1
Microwave doppler effect
: AIR area -6 to +6°
Microwave area +25 to +45°
: 12 to 24VAC ±10% (50 / 60 Hz)
12 to 30VDC ±10%
: < 2.5W (< 4VA at AC)
: See
Operation indicator table
: Opto coupler
Voltage 5 to 30VDC
Current 6mA Max. (30VDC)
:
: See
INSTALLATION 2
Safety / test output
Output hold time
Response time
Operating temperature
Operating humidity
IP rate
Category
Weight
Accessories
Performance level
: Opto coupler (NPN)
Voltage 5 to 50VDC
Current 100mA Max.
Dark current 600nA Max.
(resistance load)
: <0.5 sec.
: <0.3 sec.
: -20 to +55°C (-4 to 131°F)
: <80%
: IP54
: See
Table 1
: See
Table 1
: 320g (11.2oz )
: 1 Operation manual
2 Mounting screws
1 Mounting template
1 Area adjustment tool
1 Cable 3m (9'10")
(8 × 0.22mm² AWG24 ) *3
The specifications herein are subject to change without prior notice due to improvements.
NOTE
It is required to check the operation manual if this symbol is shown on the product.
MANUFACTURER'S STATEMENT
WARNING
Do not wash, disassemble, rebuild or repair the sensor, otherwise
it may cause electric shock or breakdown of the equipment.
Danger of electric shock
WARNING
CAUTION
NOTE
Disregard of the warning symbol can cause improper operation which may cause death
or serious injury.
Special attention is required to the section of this symbol.
Disregard of the caution symbol can cause improper operation which may cause injury of a
person or damage the object.
NOTE
Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of
a person.The meanings of the symbols are as follows.
1. This product is a non-contact switch intended for header mount or wall mount for use on an automatic sliding door.
Do not use for any other applications.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment connected to
the product.
4. Only use the product as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country in which
the product is installed.
6. Before leaving the installation site make sure that the product is operating properly and instruct the building
owner/operator on proper operation of the door and the product.
7.The product settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
The actual detection area may become smaller depending on the ambient light, the color / material of
the object or the floor as well as the entry speed of the object.
The sensor may not be activated when the entering speed of the object or a person is slower than
50mm / sec. or faster than 1500mm / sec.
NOTE
[mm (inch)]
Operation indicator table
A1:2009
EN61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3
COMPLIANCE
CAUTION
Risk of getting caught
Make sure to affix the mounting template as described in the above chart,
otherwise it can be dangerous since there may be no detection area around
the threshold. Install the sensor as low as possible on the header.
WARNING
Danger of electric shock
Do not use the sensor without the cover.
When using the cable knockout, install the sensor indoors or use the rain cover
(separately available) otherwise electric shock or breakdown of
the sensor may occur.
Before starting the procedure, make sure that the power is turned OFF.
When passing the cable through the hole, do not tear the shield
otherwise it may cause electric shock or breakdown of the sensor.
4
Wire the cable to the door controller as shown below.
1.Plug the connector.
2.Supply power to the sensor. Adjust the detection area and set the dipswitches.
(See
ADJUSTMENTS 4. Dipswitch settings
)
Place the housing cover.
If wiring is to be exposed, break the knockout.
H : Height from the floor to the bottom of the header
Y : Distance between the bottom of the header and the sensor
X : Distance between the door and the mounting surface
WARNING
Danger of electric shock
NOTE
Make sure to connect the cable correctly to the door controller before turning the power ON.
When turning the power ON or after adjusting the settings, do not enter the detection area for more
than 10 seconds in order to enable the presence detection.
Do not touch the dipswitches before turning the power ON, otherwise an error occurs.
After changing the dipswitches and/or potentiometer, make sure to push the function switch for 2 seconds.
INSTALLATION
The following conditions are not suitable for sensor installation.
-Fog or exhaust emission around the door
-Wet floor
-Vibrating header or mounting surface
-Moving objects, steel plate, emergency lights or illumination in the detection area or in vicinity
-Highly reflecting floor or highly reflecting objects around the door
NOTE
X
H
Y
Sensor
Door
Header
Floor
SPECIFICATIONS
(10)
(1)
(4)
(5)
(8)
(6)
(9)
(3)
(2)
Machinery Directive 2006/42/EC
Notified Body: TÜV SÜD Product Service GmbH, Daimlerstraße 40 60314 Frankfurt Germany
Noise level
: <70dBA
1. Affix the mounting template at the desired mounting position.
2. Drill two mounting holes of ø3.4mm (ø1/8”).
3. To pass the cable through the header, drill a wiring hole of ø8mm (ø5/16”).
4. Remove the mounting template.
5. Remove the housing cover. Fix the sensor to the mounting surface with the two mounting screws.
Refer to the chart in below.
EN ISO13849-1:2008
EN ISO13849-2:2008
EN16005:2012
EMC Directive 2004/108/EC
1
2
3
4
AIR
Microwave
Mounting height : 2.2m(7'2")
Vertical adjustment : +35°
Sensitivity : H
Area width : wide
Speed of detection object
: 50mm / sec.
Mounting height : 2.2m(7'2")
Angle adjustment : +6°
Sensitivity : M
: Emitting spots
: Detection area
: Emitting spots
(can be eliminated)
: Detection area
AutSchR (OAM-DUAL TV/TF/TT Only)
1sec.
1sec.
Set-up
Stand-by (installation mode)
Stand-by (operation mode)
Setting error
Signal saturation
Sensor failure
2nd row detection
Lookback (1st row) detection*4
3rd row detection
Microwave detection
Status
Yellow blinking
Green
Red & green blinking
Slow green blinking
Fast green blinking
Yellow
Orange
Red
Operation indicator color
Red blinking
Blue
(7)
LOOKBACK AREA
When dipswitch 15 is set to ON, the lookback area, that provides extra safety over the threshold, is activated.
In case the lookback function is not required, set dipswitch 15 to OFF.
Do not set the 2nd row overlapping the threshold regardless of the setting of dipswitch 15.
Lookback
(1st row)
2nd row
3rd row
Lookback
(1st row)
2nd row
3rd row
12 to 24VAC±10% / 12 to 30VDC±10%
Opto coupler(NPN) / Voltage: 5 to 50VDC
Form A relay
50V 0.3A Max.
Opto coupler / Voltage: 5 to 30VDC
1.White
2.Brown
3.Green
4.Yellow
5.Pink (+)
6.Blue (-)
7.Red (+)
8.Black (-)
Power
supply
Safety /
test output
Activation
output
Test input
2
1
3
4
Voltage output 3.2V@10mA
Min. 4.5V(no load)
(+)
(-)
Frequency output
100Hz±10%
1
2
3
4
Form A relay
50V 0.3A Max.
Opto coupler /
Voltage: 5 to 30VDC
5
OAM-DUAL T
OAM-DUAL TV
OAM-DUAL TF
OAM-DUAL TT
*2 : The sensor has to be connected to a door system which has a SELV circuit.
*4 : See
LOOKBACK AREA
*1 : Active infrared reflection has a presence detection function.
*3 : Overcurrent protection with less than 2A.
Table 1
Cat.
AIR
part
Microwave
part
PL
Cat.
PL
OAM-DUAL T OAM-DUAL TV OAM-DUAL TF OAM-DUAL TT
d (EN ISO13849-1 : 2008)
d (EN ISO13849-1 : 2008)
2 (EN ISO13849-1 : 2008)
2 (EN ISO13849-1 : 2008)
Test conditions required by EN16005
Floor :Grey paper
Detection object : EN 16005 CA reference body
Sensitivity : middle
Speed of detection object : 50mm / sec.
To comply with EN16005, make sure that the detection area is within the values of the chart below.
AIR detection area
The chart shows the values at depth angle +6°
AIR emitting area
A
X
G
I*
2.20 (7'2")
2.00 (6'6")
0.25 (10")
1.12 (3'8")
2.65 (8'8")
3.00 (9'10")
0.34 (1'1")
1.53 (5')
3.60 (11'10")
0.23 (9")
1.02 (3'4")
2.41 (7'11")
The values mentioned in "detection area" refer to the test conditions as described in the EN16005
(the emitting area is specified in "emitting area").
*: When installed at higher than 3.0m(9'10"), EN16005 requirements are fulfilled only within the area width "I"
of 3.6m(11'10").
[m(feet,inch)]
A
C
B
G
H
I
0
1000
(3′3")
1000(3′3")
2000(6′6")
1000
(3′3")
2000
(6′6")
2000
(6′6")
Lookback(1st row)
2nd row
3rd row
D E
F
A
B
C
D
E
F
G
H
2.20 (7'2")
0.08 (3")
0.25 (10")
0.39 (1'3")
0.65 (2'2")
1.33 (4'4")
2.70 (8'10")
0.10 (4")
0.31 (1')
3.00 (9'10")
0.11 (4")
0.34 (1'1")
0.48(1'7")
0.80 (2'8")
0.53 (1'9")
0.89 (2'11")
1.63 (5'4")
1.81 (5'11")
2.50 (8'2")
0.09 (4")
0.28 (11")
0.44 (1'5")
0.74 (2'5")
1.51(4'11")
2.00 (6'6")
0.07(3")
0.06 (2")
0.074(3")
0.08 (3")
0.07 (3")
0.05(2")
0.23 (9")
0.35 (1'2")
0.59 (1'11")
1.21 (3'12")
2.05 (6'9")
2.51 (8'3")
2.79 (9'2")
2.32 (7'7")
1.86 (6'1")
I
2.78 (9'1")
3.40 (11'2") 3.79 (12'5")
3.50 (11'6")
0.12 (5")
0.39 (1'4")
0.61 (2')
1.03(3'5")
2.11 (5'11")
0.09 (4")
3.25 (10'8")
4.42 (14'6")
3.15 (10'4")
2.52(8'3")
[mm(feet,inch)]
Maximum distance (Y)
X
2.00 (6' 6")
2.30 (7' 6") 2.50 (8' 2") 2.80 (9' 2")
0
No limit
0.05 (2")
0.13 (5")
0.13 (5")
0.14 (6")
0.10 (4")
0.11 (4")
0.12 (5")
0.12 (5")
0.12 (5")
0.15 (6")
0.10 (4”)
0.10 (4”)
0.11 (4")
0.11 (4")
0.20 (8")
-
0.09 (4”)
0.10 (4”)
0.10 (4”)
0.25 (10")
0.09 (4”)
0.30 (12")
-
-
H
0.13 (5")
-
-
-
-
0.09 (4")
[m (feet,inch)]
3.00 (9'10") 3.50 (11'6")
0.14 (6")
0.12 (5")
0.11 (4")
0.10 (4")
0.09 (4")
-
0
0
0
0
0
0
NOTE
Make sure not to mount the sensor lower than the bottom of header.
X
Mounting
surface
1.White
2.Brown
3.Green
4.Yellow
5.Pink (+)
6.Blue (-)
7.Red (+)
8.Black (-)
9.Gray/Pink (+)
10.Red/Blue (-)
Power
supply
Safety /
test output
Activation
output
Test input
(Safety)
2
1
3
4
Test input
(Activation)5
All manuals and user guides at all-guides.com
all-guides.com