34
13
Troubleshooting
Error code list
Error code and details
Cause
Action
E1000
Communications error
5/<
(
The sensor cable
is broken.
Make sure that the cable
is not damaged. If any
damage is found, contact
the dealer.
The sensor cable
is not properly
wired.
Turn off power of the
transmitter, check the
wiring, and be sure to wire
properly.
The sensor is
out of order.
The sensor must be
repaired. Contact the dealer.
E2000
Sensor processing/sensor
failure
㸰
'2
㸯
7XUE
5/<
PJ/
(
Υ
Manual cleaning
was carried out
immediately after
cleaning opera-
tion.
Wait a few seconds to
return to the measurement
value display.
When performing manual
cleaning, wait at least 5
minutes after cleaning
operation.
SC-U1 was
operated while
the sensor was
being processed.
The sensor is no longer
accepting input from
SC-U1. The display returns
to the measurement value
after a few seconds.
The sensor cable
is broken.
Make sure that the cable
is not damaged. If any
damage is found, contact
the dealer.
The following table describes error codes, causes and actions.
If you find any problem other than the error codes, refer to “When in trouble”
in the "Universal Transmitter SC-U1 Operation Manual".
When the normal condition is not recovered after the countermeasure is taken,
when any problem other than these occurs, or when requesting repairs, check