2.4

 

OPERATION

2.5

 

CONTROLS

The OSD553  automatically maintains the output video signal at 1.0

±

0.1Vpp

The OSD553 has the following controls:

LK4, LK3, LK2

Enable  the  video  mute  to operate on Channel 1 (Top), 2, 3
(Bottom).  If installed the video output is disabled when the
associated “video present indicator” changes from green to red.

LK 7, LK6, LK5

Couple channels 1, 2 and 3 to the alarm relay (if fitted).  This is
useful when the unit’s “Alarm” function is required as unused
channels can be disabled by removing the associated link.

LK1

Set to 1 if –12V is available (as is the case when used in an
OSD350 or OSD370 chassis fitted with an OSD911 or OSD922
power supply unit (PSU)) and to 3 if –12V is not available (as is
the case when an OSD921 PSU is used).

2.6

 

INDICATORS

The OSD553 has only three indicators, one for each channel.

"Video Signal Present"  

Green when a video signals is detected
Red when no video signal is detected

Note that this will glow red even if an optical signal is present but there is no video signal
transmitted by the remote transmitter.

Summary of Contents for OSD553

Page 1: ...OPERATOR MANUAL OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER ...

Page 2: ...OPTICAL SYSTEMS DESIGN DOC ID 10103502 OSD553 OPERATOR MANUAL PAGE 2 OSD553 TRIPLE VIDEO FIBRE OPTIC RECEIVER Document No 101035 Revision 02 ...

Page 3: ...ATION AND OPERATING INSTRUCTIONS 6 2 1 INTRODUCTION 6 2 2 INSTALLATION 6 2 3 OTHER CONNECTIONS 6 2 4 OPERATION 7 2 5 CONTROLS 7 2 6 INDICATORS 7 3 MAINTENANCE 8 3 1 INTRODUCTION 8 3 2 EXTERNAL INSPECTION 8 3 3 ROUTINE MAINTENANCE 8 4 WARRANTY 9 4 1 WARRANTY PERIOD 9 4 2 ALL REPAIRS 9 4 3 WARRANTY REPAIRS 9 4 4 OUT OF WARRANY REPAIRS 9 4 5 SITE REPAIRS 9 4 6 EXCLUSIONS 9 ...

Page 4: ... with OSD551 triple transmitter cards generally located in other control rooms or signal aggregation points Each of the OSD553 s three receivers has an automatic gain control that utilises the sync tips to ensure stable picture levels under all lighting conditions at the camera It is available to operate either at a wavelength of 850nm over multimode fibre OSD553 or at a wavelength of 1300nm to op...

Page 5: ...ce rms noise over 5 5MHz OPTICAL Number of fibres 3 Receiver operating wavelength 800 to 900nm OSD553 1200 to 1600nm OSD553L Receiver sensitivity 30dBm peak for 50dB SNR OSD553 31dBm peak for 50dB SNR OSD553L Receiver saturation 14dBm peak OSD553 15dBm peak OSD553L Optical connectors ST standard Others optional consult factory PHYSICAL Power Requirements 12V 200mA 12V 100mA OR 12V 300mA Dimensions...

Page 6: ...switcher to the OSD553 Ensure that correctly terminated 75Ω BNC patch leads are used Fix the unit into the chassis using the captivated screws and connect the optical cable If a video signal is being transmitted through the link the appropriate Video Signal Present LEDs will glow green on the front panel of OSD353 receiver If not this LED will glow red Note that the card can be plugged in or out o...

Page 7: ... fitted This is useful when the unit s Alarm function is required as unused channels can be disabled by removing the associated link LK1 Set to 1 if 12V is available as is the case when used in an OSD350 or OSD370 chassis fitted with an OSD911 or OSD922 power supply unit PSU and to 3 if 12V is not available as is the case when an OSD921 PSU is used 2 6 INDICATORS The OSD553 has only three indicato...

Page 8: ...re extremely expensive and can be damaged by failure of any portion of their support circuitry 3 2 EXTERNAL INSPECTION Visually check the following Check that the power supply voltages are correct on the Power Supply Unit 12 to 17VDC and 12 to 17VDC for the OSD911 and 11 5 to 12 5VDC on the OSD921 Check that video signal is connected to the remote video transmitter and that the OSD553 has been cor...

Page 9: ...hall be at customer s expense and freight back to the customer will be at Optical Systems Design s expense 4 4 OUT OF WARRANY REPAIRS Optical Systems Design reserves the right to repair or replace any faulty goods Freight costs and insurance for both journeys are met by the user All equipment repaired by Optical Systems Design will have a 3 month warranty from the date of dispatch 4 5 SITE REPAIRS...

Reviews: