background image

Opticon 

CRD9823-RU 

Specifications Manual 

 
 
 

 

11 

8.  Labels 

The serial number shown below is affixed to the specified location on the cradle. 

8.1.  Product label 

 

Figure 5: Product  label on the bottom of the cradle 

8.2.  Interface Label 

 

Figure 6: Label on the back side of the cradle 

Summary of Contents for CRD9823-RU

Page 1: ...CRD9823 RU Data Collector Cradle Specifications Manual ...

Page 2: ...t are defective in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental damages ...

Page 3: ...signment 7 6 1 1 DC Power Supply Connector EIAJ Type 3 7 6 1 2 Connector for USB on PC Side USB Type B 7 6 1 3 Connector for RS 232C on PC Side Ten electrode modular jack 7 6 2 Communications Interface 8 6 2 1 Baudrate Configuration using DIP switches 8 6 2 2 Baud Rate Configured Using Software 9 7 Cables and Connectors 10 7 1 RS232 C Cable 10 7 2 USB A B Cable 10 8 Labels 11 8 1 Product label 11 ...

Page 4: ...ming when software is configured 9 Figure 3 RS 232C cable 10 Figure 4 USB cable 10 Figure 5 Product label on the bottom of the cradle 11 Figure 6 Label on the back side of the cradle 11 Figure 7 Individual packaging specification 12 Figure 8 Collective packaging specification 13 Figure 9 Mechanical drawing 16 ...

Page 5: ...infrared data communication IrDA1 2 low power and can communicate with a host computer via either USB USB 2 0 CDC class virtual comm port or RS232C The CRD9823 RU has three status LED s a red LED that indicates that the power is switched on a green LED that blinks when the cradle receives data via IrDA and a yellow LED that blinks when data is received via USB or RS232 The baud rate for RS232 IrDA...

Page 6: ... be 6V 2A It is not possible to power the cradle via USB 5 1 Absolute Maximum Ratings Parameter Value Unit Power supply voltage VCC to GND 0 3 to 6 5 V Input voltage D D 0 5 to 0 5 V Input voltage RS 232C IN 30 V Input voltage RS 232C OUT 15 V 5 2 Recommended Operating Conditions Item Symbol Conditions Min Typ Max Unit Power supply voltage VDD DC power supply 5 5 6 0 6 5 V ...

Page 7: ...r USB on PC Side USB Type B Pin Signal Name I O Notes 1 VBUS P USB bus power supply 2 D I O Data 3 D I O Data 4 GND P Ground 6 1 3 Connector for RS 232C on PC Side Ten electrode modular jack Pin Signal Name I O Notes 1 GND P Ground 2 CTS I For baud rate software control 3 TXD O Transmit data to PC 4 RXD I Receive data from PC 5 NC Not connected 6 GND P Ground 7 NC Not connected 8 DSR I For baud ra...

Page 8: ... switches To disable software configuration set SW4 to OFF Baud rate can be configured using SW1 SW3 as listed in the table below Baud rate DIP Switch SW1 SW2 SW3 SW4 115 2 kbps ON ON ON OFF 57 6 kbps OFF ON ON OFF 38 4 kbps ON OFF ON OFF 19 2 kbps OFF OFF ON OFF 9600 bps ON ON OFF OFF 4800 bps OFF ON OFF OFF 2400 bps ON OFF OFF OFF 1200 bps OFF OFF OFF OFF Figure 1 DIP switch settings Remove the ...

Page 9: ... host computer set SW4 to ON The other DIP switches are not used when SW4 is ON CTS Line DSR Line Baud Rate Remarks Edge 0 pulse 115 2 kbps Reset Pulse Count 1 pulse 57 6 kbps 2 pulse 38 4 kbps 3 pulse 19 2 kbps 4 pulse 9600 bps 5 pulse 4800 bps 6 pulse 2400 bps 7 pulse 1200 bps Figure 2 Signal timing when software is configured ...

Page 10: ...ht Diameter φ3 8 0 15 mm Length 1500 100 0 mm Cores 8 insulated wires 1 conductive wire Connectors Left RJ50 10 pin modular jack Right DB9 female 7 2 USB A B Cable Figure 4 USB cable Type Straight Diameter Φ4 7 0 15 mm Length 1500 50 mm Cores 4 insulated wires 1 conductive wire Connectors Left USB B type Right USB A type ...

Page 11: ... Manual 11 8 Labels The serial number shown below is affixed to the specified location on the cradle 8 1 Product label Figure 5 Product label on the bottom of the cradle 8 2 Interface Label Figure 6 Label on the back side of the cradle ...

Page 12: ...D9823 RU Specifications Manual 12 9 Packaging Specifications 9 1 Individual Packaging Put the cradle in a protective foam bag and place it in an individual packing box Figure 7 Individual packaging specification ...

Page 13: ...O mark labeled on the package tray or package box guarantees that the applicable product has passed our test of RoHS restrictions compliance the restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC However this document does not have any legal weight in the European Union ...

Page 14: ...5 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 10 2 RoHS RoHS The restriction of the use of certain hazardous substances in electrical and electronic equipment 2002 95 EC ...

Page 15: ...ature range Do not subject the cradle to temperatures outside the specified storage temperature range Do not forcibly bend the cables especially at low temperatures Foreign Materials Do not immerse the cradle in liquids Do not subject the cradle to chemicals Other Do not disassemble this product This cradle may degrade the reception of nearby radio television sets The cradle may be damaged by high...

Page 16: ...S 232C communication connector to the host computer 4 Power LED Red Red LED lights when the power is on 5 IrDA reception LED Green Green LED blinks when receiving data via IrDA 6 IrDA transmission LED Yellow Yellow LED blinks when transmitting data via IrDA 7 IrDA communication window IrDA communication window 8 Charging terminal Charging Terminal to the OPL 97xx 9 Charging terminal Charging Termi...

Reviews: