F-100 SR
1st
9
SPECIFICATIONS MANUAL
Technical Specifications
8
The conditions for technical specifications are as follows, unless otherwise specified in each section.
Conditions
Ambient Temperature and Humidity
Room temperature, room humidity
Ambient Light
500 to 1500 lux
Angles
α = 0°, β = +15°, γ = 0° (refer to figure 6)
Curvature
R =
∞
Power Supply Voltage
5.0 V
PCS
0.9 or higher
Scanning Test
More than 630 times success during 700 scans.
Barcode Test Sample
Specified in each section
Barcode Test Sample
8.1
Code39
Resolution
Code type
PCS
Barcode
width*
Quiet Zone
Digits
1.0mm
Code 39
0.9
53mm
20mm
1
0.5mm
54mm
10mm
4
0.25mm
42mm
5.1mm
8
0.19mm
60mm
5.1mm
17
80mm
5.1mm
24
0.15mm
60mm
5.1mm
10
0.125mm
16mm
5.1mm
4
0.19mm
0.45
60mm
5.1mm
17
EAN/JAN
Resolution
Code type
PCS
Barcode
Width*
Quiet Zone
Digits
0.26mm
EAN/JAN
0.9
30mm
10mm
13
0.26mm
EAN/JAN
0.9
22.5mm
10mm
8
* The width includes the quiet zone.