F-100 SR
1st
11
SPECIFICATIONS MANUAL
Printed Contrast Signal (PCS)
8.4
PCS 0.45 or higher
Conditions
MRD
≥
32% (
≥
80% reflectivity of space and quiet zone)
Distance
35 mm from the front edge of the scanner
Barcode width
Maximum 60mm
Barcode
Code 39. Resolution = 0.19mm / PCS 0.45, specified in Section 8.1.
MRD = Minimum reflectance of white space
– Maximum reflectance of black bar
PCS =
Reflectance of white space
– Reflectance of black bar.
Reflectance of white space
Note: Be sure to keep the optical window clean without dirt or scratches, or it may deteriorate the reading
performance.
Minimum Resolution
8.5
0.125mm (Code 39 specified in Section 8.1)
Conditions
Bar code
Above code specified in Section 8.1.
Distance
35±5 mm from the front edge of the scanner
Angle
α = 0°, β = + 15°, γ = 0°
Curvature
R =
∞
Barcode Width
8.6
80 mm
Conditions
Barcode
Code 39. Resolution = 0.19mm / PCS 0.9, specified in Section 8.1.
Distance
35 mm from the front edge of the scanner
Angle
α = 0°, β = + 15°, γ = 0°
Curvature
R =
∞
Figure 5: Barcode width
80
[Unit: mm]
35