SPECIFICATIONS MANUAL
Scan Key Durability
10.5
Activating the scanner by pressing the trigger shall be possible after the following scan key strength
test.
Scan Key Strength Test:
Affix the scanner as shown in the following picture. Press and release the
scan key by a push rod with a diameter of 10mm with a force of 9.8N (1kgf) and repeat this 5 million
times.
Figure 19: Scan key durability
Cable Strength
10.6
There shall be no malfunction after the following cable strength test.
Cable Strength Test:
Affix the scanner to an immovable object and pull the cable using a force of
24.5N (2.5 kgf static loading) for 60 seconds.
Cable Bending Strength
10.7
There shall be no malfunction after the following cable bending test.
Cable Bending Test:
Add a load of 4.9 N (500 gf) to the cable and flex it 60° in both directions.
Repeat this 700 times.
Figure 20: Cable Bending Strength