Chapter-8
Read Options
L-46X User's Manual
102
1st
Auto Trigger
8.3
When auto trigger is enabled, the scanner automatically detects an object in front and starts reading it.
Normal Auto Trigger
8.3.1
There are two modes for auto trigger.
● Presentation auto trigger mode
This mode is meant for applications where the scanner is fixed and codes are presented.
● Handheld auto trigger mode
This mode is meant for applications where the module is not fixed.
Item
Command
Description
Default
Auto trigger
+F
Disable presentation auto trigger
+I
Enable presentation auto trigger
Auto trigger Mode
[DL5
Presentation auto trigger mode
[DL6
Hand held auto trigger mode
Auto Trigger Sensitivity
8.3.2
The detection sensitivity can be adjusted. The sensitivity varies with the ambient environment and
adjustment may be necessary.
Item
Command
Description
Default
Auto trigger sensitivity
[XMF
Sensitive
[XMH
Normal
[XMJ
Insensitive
Double read reset time
8.3.3
This allows setting of time interval before the same code can be decoded again in auto trigger mode.
When a code with different data is read, this will be reset.
Item
Command
Description
Default
(valid range)
Double read reset
time
[D3R
Qa Qb
Qc Qd
Double read reset time
(1000a+100b+10c+d) [ms]
700 ms
(0-9999)
*When 0 second is set, the same code will not be decoded.