Chapter-3
Configurations
L-46X User's Manual
24
1st
Save Settings
3.2.2
The Active Settings can be written into the “Startup Settings”.
Item
Command
Description
Remark
Save settings
Z2
Save the Active Settings as Startup Settings
Command only
* Place “Z2” at the end of command packet to be saved.
* Saving settings for more than 30,000 times may destroy memory. Avoid saving every time.
* There are options that will not be enabled until “Save settings” is sent, such as baud rate setting.
Custom Setting
3.2.3
Item
Command
Description
Remark
Custom settings
[BAP
Read out Custom Settings
[BAQ
Save to Custom Settings
* Place “[BAQ” at the end of command packet to be saved.
* To save both “Custom settings” and “Active Settings” at same time, send “[BAQZ2”.
* Custom settings for more than 30,000 times may destroy memory. When setting frequently, avoid saving every
time.
Various Interface Switching
3.2.4
Various interface factory setting can be change. Cable changing is required for USB and RS-232C.
This setting is also saved when updating firmware.
Switch to USB-HID
Item
Command
Menu
Remark
Change interface to
USB-HID
[X.ZSU[X.ZZ2
Confirm cable
Switch to USB-COM
Item
Command
Menu
Remark
Change interface to
USB-COM
[X.Z[C01[X.ZZ2
Confirm cable
Switch to RS-232C
Item
Command
Menu
Remark
Change interface to
RS-232C
[X.ZU2[X.ZZ2
Confirm cable