Chapter-6
Code Options
L-46X User's Manual
86
1st
Setting of Number of Characters
6.4
If you are going to read codes of fixed length, it is recommended to configure the scanner for that fixed
number of characters. The scanner will verify that codes read are of the correct length and rejects
codes that do not have the specified length. The advantage of setting a fixed length is that it provides
protection against spurious short scans of codes, possible with code types that do not provide
sufficient security against partial scans (e.g. Interleaved 2 of 5). The length checking is done on the
code data and is not affected by options such as (not) transmit start/stop character or check digit.
Setting the number of characters does not affect fixed length codes, such as EAN-13.
Fixed Length ON, Minimum / Maximum Length for Selected Codes
6.4.1
This option enables fixed length and minimum / maximum length checking for each code types and
will only affect the specified code types.
Configuration with commands
Item
Command
Description
Default
(valid range)
Fixed length
Specify Code
Input length of digits Fixed length for selected codes
Length: (1000a+100b+10c+d)
(0-8000)
Qa
Qb
Qc Qd
Configuration example
Command
Fix Code39 length to 6 digits
<Esc>[DC1Q6<CR>
Fix Code39 length to 6 digits and 12 digits
<Esc>[DC1Q6[DC1Q1Q2<CR>
Fix Code39 length to 6 digits and Interleaved 2 of 5 to 12 digits
<Esc>[DC1Q6[DC4Q1Q2<CR>
Clear fixed length for Code39
<Esc>[DC1<CR>
Set minimum length for Interleaved 2 of 5 to 4 digits
<Esc>[DB4Q4<CR>
Clear minimum length for Interleaved 2 of 5
<Esc>[DB4<CR>
Set maximum length for Code39 to 12 digits
<Esc>[DA1Q1Q2<CR>
Clear max length for Code39
<Esc>[DA1<CR>
Set max length for PDF417 to 20 digits and QR code 125 digits
<Esc>[DALQ2Q0[DAJQ1Q2Q5<CR>