background image

Chapter-2 

Before Using

 

L-46X User's Manual    

1st

                                                                               

 

 

 

 

Model Details 

2.1

The L-46X model is constructed by a combination of following. 

Model 

name 

  Focus    Vibrator    Housing   

Interface 

 

Cable 

length 

 

Optional 

AC adapter 

 

Optional 

Stand 

L-46X 

 

None 

or 

UD 

 

-V 

or 

None 

 

-BLK 

or 

-WHT 

 

-USB 

 

None (20) 

 

None 

 

+STD 

or 

None 

-15 

-24 

-28 

-RS232C 

None (20) 

+PS 

-24 

-28 

-RS232C(9P) 

None (20) 

None 

 

 

Standard 

2.1.1

The following specs are the standard products. 

Standard 

Description 

L-46X-BLK-USB+STD 

Black housing USB-HID 2.0 m cable with stand 

L-46X-BLK-PS+STD 

Black housing RS-232C 2.0 m cable with AC adapter and stand 

Note: Other combinations only as special order, please contact sales offices for this

 

 

Model Description 

2.1.2

● Focus 

 

● Housing 

Symbol 

Description 

 

Symbol 

Description 

None 

Standard focus 

 

-BLK 

Black housing 

UD 

Ultra high resolution 

 

-WHT  

White housing 

 

● Interface 

 

● Cable Length 

Symbol 

Description 

 

Symbol 

Description 

-USB 

USB interface (default is USB-HID) 

 

None 

Cable length 2.0 m 

-RS232C 

RS-232C interface with power supply 
(external AC adapter power supply spec) 

 

-24 

Cable length 2.4 m 

-RS232C(9P) 

RS-232C interface (power supply input connected to D-sub 9pin 9)   

-28 

Cable length 2.8 m 

 

 

 

 

 

● Optional AC Adapter 

 

● Optional Stand 

Symbol 

Description 

 

Symbol 

Description 

None 

AC adapter not included. 

 

None 

Dedicated Auto Trigger stand (STD-46) is not included. 

+PS 

AC adapter included 

 

+STD 

Dedicated Auto Trigger stand (STD-46) is included. 

 

 

 

Note: Auto Trigger stand is also sold separately. 

 
 

 

Summary of Contents for L-46X

Page 1: ...L 46X 2D Handy Scanner User s Manual ...

Page 2: ...ive in materials or workmanship with proper use during the warranty period Opticon is not liable for damages caused by modifications made by a customer In such cases standard repair charges will apply If a product is returned under warranty and no defect is found standard repair charges will apply Opticon assumes no liability for any direct indirect consequential or incidental damages arising out ...

Page 3: ...lug the cable and AC adapter then contact your dealer if If the cable jacket tears open or separates from the connector If any core wire become exposed If the cable generates heat even if it looks normal Continued use in any of these conditions may cause malfunction overheating and or fire Operating environment Do not use this product at temperatures outside the specified range Do not use this pro...

Page 4: ...nce that may cause undesired operation Regulatory Compliance 1 LED Safety IEC 62471 2006 Exempt Risk Group 2 EMC EN 55024 2010 A1 2015 EN 55032 2012 AC 2013 Class B FCC Part 15 Subpart B Class B VCCI クラス B Disclaimer OPTOELECTRONICS CO LTD will not bear any responsibility in case of malfunction accident repair and damage assurance この装置は クラスB情報技術装置です この装置は 家庭環境で使用することを目的としていますが この装置がラジオやテレビジョン受信機に近...

Page 5: ...L 46X User s Manual iii 1st Revision History Document Name L 46X User s Manual Edition Date Page Section Description of Changes 1st 2019 03 06 Initial release ...

Page 6: ...USB Suspend Mode Transition Diagram 12 2 7 3 Buzzer and Status LED 13 2 8 Cable Desorption Method 14 2 9 Removing Cable 14 2 9 1 Attaching Cable 15 2 9 2 Optional Accessories 16 2 10 Stand STD 46 16 2 10 1 Holder STD 4101 17 2 10 2 Various Exchange Cable 17 2 10 3 3 Configurations 18 Configuring with Commands 19 3 1 Command Packet 19 3 1 1 Configuring with 2D Menu 20 3 1 2 Configuring with 1D Menu...

Page 7: ... General 32 4 4 Indicator Timing 32 4 4 1 5 Interface 33 USB HID 34 5 1 USB HID Basic Information 35 5 1 1 Connection Confirmation USB HID 36 5 1 2 NumLock CapsLock control 36 5 1 3 Data Output Speed USB HID 37 5 1 4 Inter Character Delay USB HID 37 5 1 5 Keyboard Language 38 5 1 6 Trouble Shooting USB HID 39 5 1 7 USB COM 40 5 2 USB COM Basic Information 41 5 2 1 Integration USB driver 41 5 2 2 C...

Page 8: ...n 61 6 2 4 Add on waiting time 61 6 2 5 ECI Protocol Output 62 6 2 6 OCR Free Edit 63 6 2 7 Setting of Code Specific Options 64 6 3 UPC 64 6 3 1 EAN JAN 67 6 3 2 Code 39 and It Pharm Code 32 71 6 3 3 Codabar 73 6 3 4 Interleaved 2 of 5 and S Code 75 6 3 5 Code128 76 6 3 6 IATA 77 6 3 7 MSI Plessey 77 6 3 8 UK Plessey 77 6 3 9 Telepen 77 6 3 10 Code 11 78 6 3 11 Korean Postal Authority 78 6 3 12 GS...

Page 9: ...tivity 102 8 3 2 Double read reset time 102 8 3 3 Read Time Adjustment 103 8 3 4 Auto Trigger Sleep Mode 103 8 3 5 Detection Mode 103 8 3 6 Illumination and Aiming 104 8 4 Reading LED Illumination 104 8 4 1 LED Aiming 104 8 4 2 Batch Reading Data Edit Function 105 8 4 3 Data Edit Function 105 8 4 4 9 Appendix 106 Code ID Table 107 9 1 Opticon Code ID prefix suffix value 107 9 1 1 Code Option AIM I...

Page 10: ...L 46X User s Manual viii 1st GS1 Composite Code 128 9 3 4 2D Code 130 9 3 5 OCR Font Machine Readable Travel Document 131 9 3 6 OCR Font Free OCR Edit 132 9 3 7 ...

Page 11: ...Chapter 1 Abstract L 46X User s Manual 1 1st 1 Abstract This document provides the user s manual for the L 46X 2D handy scanner hereafter called scanner 1 1 Feature of the Scanner 1 2 Flow to Integrate ...

Page 12: ...ng This scanner features a unique script program function called Data Editing which gives a user an almost unlimited flexibility to format the scanned data before it is sent out Up to 16 barcodes can be partially combined and fixed parts can be added subtracted or substituted before its final output The output editing process such as GS1 format can also be configured easily Anti microbial Anti Yel...

Page 13: ...essary tools from our website Setting Image acquisition confirm communication UniversalConfig UniversalConfig WIME USB COM USB Driver COM output HID output conversion WIME 3 Setting and Testing In the actual enviroment evaluate the optimum setting according to the operation and perform a reading test Configurations Refer to 3 Indicator Refer to 4 Interface Refer to 5 Code Options Refer to 6 String...

Page 14: ...llowing explains the items required before using 2 1 Model Details 2 2 Package Contents 2 3 Detailed View 2 4 Connect to the Host 2 5 How to Read 2 6 Reading Range 2 7 Operation Transition 2 8 Buzzer and Status LED 2 9 Cable Desorption method 2 10 Optional Accessories ...

Page 15: ...ecial order please contact sales offices for this Model Description 2 1 2 Focus Housing Symbol Description Symbol Description None Standard focus BLK Black housing UD Ultra high resolution WHT White housing Interface Cable Length Symbol Description Symbol Description USB USB interface default is USB HID None Cable length 2 0 m RS232C RS 232C interface with power supply external AC adapter power su...

Page 16: ...t Please check before using Following are included to USB interface model Scanner with cable L 46X Quick Start Guide 1 copy Following are packed to RS 232C interface model Scanner with Cable AC adapter with AC plug L 46X Quick Start Guide 1 copy L 46X L 46X USB HID USB COM Interface Model RS 232C Interface Model ...

Page 17: ...ED Light blue LED light indicates good read When Auto trigger mode is enabled by placing the scanner in the dedicated STD 46 stand the status LED lights up in blue to indicate Auto Trigger mode Buzzer Orifice Sound from a built in buzzer comes out through these holes When they are covered the buzzer sound will be diminished The sound varies depending on the settings Buzzer settings are configurabl...

Page 18: ...hts When indicator operation is completed scanner becomes readable D Sub 9pin female specification Pin No Signal name Notes Pin No Signal Name Notes Pin Assignment 1 Shield Open not connected 6 Connected to pin 4 2 TxD 7 CTS 3 RxD 8 RTS 4 Connected to pin 6 9 NC Open not connected 5 GND Case FG Shield RS 232C interface has AC adapter included 9 pin power supply model are also available Host USB Co...

Page 19: ...2 5 1 The scanner read target code by acquiring the image Reading starts by triggering with green aiming as a guide normally reads around 50 mm from the front edge of scanner Hands Free 2 5 2 When installing the scanner to dedicated stand STD 46 automatically shifts to auto trigger operation by magnet switch Normally reads by holding target code to around 50 mm from front edge of the scanner When ...

Page 20: ... and imaging range Since the dotted line in the image above is not actually visible LED aiming will be the target when reading Refer to 9 2 2 for reading depth of field Refer to 8 1 3 for the setting to read only center of LED aiming Appropriate LED aiming If the code including quiet zone is within the view angle 360 rotation reading is possible Not appropriate LED aiming ...

Page 21: ...ight blue and warm white LED slightly on Auto trigger sleep When no detection continues for 5 seconds default setting while in the auto trigger mode scanner shift to auto trigger sleep which detects with the warm white LED turned off Operation current transition USB HID Status Typ Unit Reading 340 mA Auto trigger standby 160 mA Standby 55 mA Power OFF Standby Auto trigger Read Auto trigger sleep P...

Page 22: ...nsition Diagram 2 7 3 The scanner supports suspend mode and remote wakeup with USB interface In USB suspend mode the scanner operates as following state transition Read Operation Enable Read Operation Disable Read operation enable command Read operation disable command USB bus Active USB suspend mode USB bus shift to active status or Event Pull trigger reading success receipt command When scanner ...

Page 23: ...u Reading sound When reading start ZZ menu code Middle Middle low Middle high tone Yellow Enable Fixed When reading defined menu code Middle Middle low Middle high tone Yellow Enable Fixed When reading not defined menu code Low tone 2 times Red Enable Fixed When reading end ZZ menu code Middle Middle low Middle high tone Yellow Enable Fixed When save setting is complete Middle Middle low Middle hi...

Page 24: ...host and follow the steps below to remove When changing interface interface setting change is also required Refer to 3 2 4 for interface switching setting menu Step1 Step2 Rotate the case removing stopper for counterclockwise 90 Pull out the case removing stopper from grip end Step3 With the case removing stopper removed from the grip end carefully pull out the cable Grip end Case removing stopper...

Page 25: ...s also required Refer 3 2 4 for interface switching setting menu Step1 Step2 Confirm the connector insert direction of the cable unit and insert into grip end Match the direction of dent mark on the case removing stopper and grip end and insert Step3 Step4 Rotate the case removing stopper for clockwise 90 After rotation case removing stopper dent mark position is as above drawing Grip end Case rem...

Page 26: ...tand that supports auto trigger stand mode Automatically shift to auto trigger mode by magnet switch Stand STD 46 2 10 1 Included to scanner depend on specification Model number STD 46 Weight Approx 365 g Mechanical drawing Unit mm Turn lock Flexible arm 106 146 224 Flexible arm Turn lock ...

Page 27: ...X User s Manual 17 1st Holder STD 4101 2 10 2 STD 4101 is a holder to place the scanner Mechanical Drawing Various Exchange Cable 2 10 3 Various exchange cable are sold separately 85 40 φ4 5 φ7 70 3 For desk mounting 2 places 75 ...

Page 28: ...6X User s Manual 18 1st 3 Configurations This chapter explains the scanner configuration default setting and saving setting and basic commands 3 1 Configuring with Commands 3 2 Command Packet Sending Precautions 3 3 Basic Commands ...

Page 29: ... Command ID 1 Command Terminator 2 ESC 0x1B None 1 2 digits ASCII CR 0x0D 0x5B 3 digits ASCII 1 It is possible to send multiple command IDs between a single header and terminator except for single digit IDs 2 A combination of command header STX 0x02 and terminator ETX 0x03 is also possible Input examples 1 digit command ESC Δ CR 2 digit command ESC ΔΔ CR 3 digit command ESC ΔΔΔ CR Two 2 digit comm...

Page 30: ...y one 2D menu code Scanning a 2D menu code will always perform a save settings upon completion so a Z2 command to save current settings is not needed Data Packet MENU_OPTO ZZ MenuCommand 1 MenuCommand 2 ZZ OTPO_UNEM MENU_OPTO Start key Separator ZZ Start menu Separator Multiple sets allowed Any menu command U2 etc Separator ZZ END menu Separator OTPO_UNEM Stop key 2D menu code can be created at Un...

Page 31: ...anner now enters menu mode Scan one or more desired options Multiple menu codes can be read when you want to configure more than one option Read END menu code ZZ All the settings are saved in non volatile memory 1D Menu codes encode an ID consisting of two to five alphanumeric characters 1D Menu codes are Code39 labels with modified start stop characters and therefore the scanner will not acknowle...

Page 32: ...32C cable Force initialization Power off the scanner remove the power Press and hold the trigger key Power on the scanner while pressing the trigger Keep pressing trigger While the Status LED is flashing hold trigger key for 10 seconds The recovery signal will sound and the status LED should stop flashing Trigger key should now be operational and the scanner should be able to read barcodes During ...

Page 33: ...efault setting is the same as the initial setting described in this manual Various interfaces require switching setting Each interface Default Setting 3 2 1 The Active Settings can be returned to the factory default settings Set the command that corresponds to the interface being used Item Command Interface Description Remark Factory Default Settings SU USB HID Restore USB HID to factory default s...

Page 34: ...out Custom Settings BAQ Save to Custom Settings Place BAQ at the end of command packet to be saved To save both Custom settings and Active Settings at same time send BAQZ2 Custom settings for more than 30 000 times may destroy memory When setting frequently avoid saving every time Various Interface Switching 3 2 4 Various interface factory setting can be change Cable changing is required for USB a...

Page 35: ...nd Description Default ACK NAK WC Enable ACK NAK for serial commands WD Disable ACK NAK for serial commands Enable Disable 2D Menu Code 3 3 3 To enable disable the processing of 2D menu codes use the settings below Setting Disable 2D menu codes is recommended when 2D menu codes are not used Item Command Description Default Enable Disable 2D menu code D1Y Enable 2D menu code D1Z Disable 2D menu cod...

Page 36: ...to 8 1 2 is set to 0 seconds Y0 command the read time with the Z command will be Indefinitely and reading will continue until a Y command is received Item Command Description Remark Trigger Command Z Start the read cycle Command only Y Stop the read cycle Direct Numerical Input Command 3 3 7 When a command requires additional numerical input the commands below can be used Use these in one packet t...

Page 37: ...ter 4 Indicator Options L 46X User s Manual 27 1st 4 Indicator Options This chapter describes the options for Buzzer and Good Read LED 4 1 Buzzer 4 2 Status LED 4 3 Good Read Aiming 4 4 Indicator in General ...

Page 38: ...cription Default Buzzer Disable Enable W0 Disable buzzer W8 Enable buzzer Buzzer duration Item Command Description Default Buzzer duration W7 Buzzer duration 50 ms EFW Buzzer duration 75 ms W4 Buzzer duration 100 ms W5 Buzzer duration 200 ms W6 Buzzer duration 400 ms Buzzer tone Item Command Description Default Buzzer tone W1 Middle frequency buzzer 3000 Hz 2600 Hz W2 2 steps buzzer high low buzze...

Page 39: ...When one code is decoded an intermediate buzzer sounds to indicate that the code is decoded but it does not yet meet the conditions to output data For instance suppose five codes reading is set in buffer mode the intermediate buzzer then sounds after the decoding of the 1st 2nd 3rd and 4th code and a good read buzzer finally sounds when the last code is decoded after which the data is output The d...

Page 40: ...ptical power s initial setting Light Situation Red Optical Power Green Optical Power Blue Optical Power Good read 0 OFF 1 20 2 80 Reading NG 3 100 0 OFF 0 OFF Installed to stand 0 OFF 0 OFF 1 20 Color and command example of Good read Color Command Example Color Command Example White EG2Q0Q2Q2Q2 Red EG2Q0Q2Q0Q0 Green EG2Q0Q0Q2Q0 Blue EG2Q0Q0Q0Q2 Orange EG2Q0Q3Q1Q0 Yellow EG2Q0Q3Q2Q0 Cyan EG2Q0Q0Q2Q...

Page 41: ...ion Default Good Read Aiming EF3 Qa Qb Qc a Setting items 0 Indicator frequency 1 First indicator duration after reading b Numerical setting 10b c Indicator frequency 00 99 times Indicator duration 00 99 x10 ms Indicator frequency 0 time Indicator duration 100 ms c Setting example Lights 2 times After 100ms Default Command EF3Q0Q0Q2 Set first indicator duration after reading to 500 ms Continue to ...

Page 42: ...ngs for each indicator are described below Indicator Timing 4 4 1 The indicators can be activated after decoding a code and before or after transmitting the data Item Command Description Default Remark Indicator timing VY Before data transmission soon after decoding VZ After data transmission ...

Page 43: ... Interface L 46X User s Manual 33 1st 5 Interface The scanner support USB HID USB COM and RS 232C interface This chapter explains each interface in detail 5 1 USB HID 5 2 USB COM 5 3 RS 232C 5 4 Common Settings ...

Page 44: ...hapter explains USB HID interface settings 5 1 1 USB HID Basic Information 5 1 2 Connection Confirmation USB HID 5 1 3 NumLock CapsLock control 5 1 4 Data Output Speed USB HID 5 1 5 Inter Character Delay USB HID 5 1 6 Keyboard Language 5 1 7 Trouble Shooting USB HID ...

Page 45: ... No control Data transmit speed Use when outputting data with high speed Initial setting 4 ms Setting range 1 ms 16 ms Data transmit interval Inter character delay Use when data is missing Initial value no interval Suspend mode Remote wakeup Use when host system is using suspend Initial value Valid Keyboard language Set according to the keyboard language Initial value English USA Character code Se...

Page 46: ...ntrol 5 1 3 Set NumLock and CapsLock control method when sending data Item Command Command description Initial setting Notes NumLock control RN Numeric value does not use numeric keypad RM Numeric value use numeric keypad A Follow NumLock status 1 CapsLock control 5Q No control 8A Invert CapsLock status 2 2U CapsLock automatic control 3 1 Only use numeric keypad when NumLock is ON 2 When starting ...

Page 47: ...fer interval Interval 10a b ms Unit 4 ms 1 16 ms Setting example Set the transmit interval to 1 ms fastest Command E9MQ1 Set the transmit interval to 10 ms Command E9MQ1Q0 Inter Character Delay USB HID 5 1 5 The inter character delay introduces a configurable delay after each transmitted character This may be used if the host does not support flow control and is not capable of handling the receive...

Page 48: ...rman Windows 1252 KI French Windows 1252 OW Italian Windows 1252 KJ Spanish Windows 1252 PH Portuguese Windows 1252 PL Swiss French Windows 1252 PK Swiss German Windows 1252 PI Dutch Windows 1252 PJ Belgian Windows 1252 PD Swedish Windows 1252 PG Finnish Windows 1252 KK Danish Windows 1252 PE Norwegian Windows 1252 WF Czech Windows 1250 BAY Hungarian Windows 1250 BPJ Turkish Windows 1254 EF4 Russi...

Page 49: ...WIME with USB COM Refer to 5 2 6 Line break is doubled Set the suffix additional setting according to the host side application s line break Cannot output images Cannot transfer images The scanner does not appear in Device Manager Restart unexpectedly Error beep sounds and does not output by reading Check that USB cable is properly connected Ensure that connected USB port is operating properly Con...

Page 50: ... 5 2 This chapter explains USB COM interface settings 5 2 1 USB COM Basic Information 5 2 2 Integration USB driver 5 2 3 Connection Confirmation USB COM 5 2 4 Fixed UBS COM Port 5 2 5 Connection Method 5 2 6 COM to HID Output 5 2 7 Trouble Shooting USB COM ...

Page 51: ...r Fixing COM number is possible Default not fix Integration USB driver 5 2 2 USB driver is required to connect to the PC via USB COM interface Please download the USB driver from our website and install appropriately according to the attached documents Connection Confirm 5 2 3 USB COM interface confirm the connection by following procedure For Windows 10 Install Opticon USB driver 1 Connect the sc...

Page 52: ...Method 5 2 5 Connect to the host PC by following procedure 1 Start the tool to serial communicates emulator or UniversalConfig 2 Connect to the COM port confirmed at 5 2 3 Connection 3 For Command packet refer to 3 1 1 COM to HID Output 5 2 6 WIME Windows NET Application allows to convert data received by the scanner via virtual COM port USB COM to HID like and transfer to the application which ha...

Page 53: ... laptop or hub supply capacity may insufficient Remove from the USB port at once and after a while insert again Insert to different port Error beep sounds and does not output by reading In addition to above Open the COM port with the communication tool Cannot connect Cannot open COM port Confirm the COM port number by device manager Refer to 5 2 3 for how to check Close the tool and re open it Ope...

Page 54: ...t RS 232C 5 3 This chapter explains RS 232C interface settings 5 3 1 RS 232C Basic Information 5 3 2 Baud Rate Transfer Speed 5 3 3 Character Format 5 3 4 Handshaking Flow Control 5 3 5 Inter Character Delay RS 232C 5 3 6 Trouble Shooting RS 232C ...

Page 55: ...lay Baud Rate Transfer Speed 5 3 2 The baud rate is the rate at which bits are transmitted from the scanner to the host and vice versa Both the scanner and the host must be set to the same baud rate The following commands can be used to configure the baud rate Z2 safe settings in non volatile memory needs be used after these commands to activate and save the new configuration Item Command Descript...

Page 56: ...these commands to activate and save the new configuration Item Command Description Default Remark Data bit L0 7 data bits Enabled after sending Z2 L1 8 data bits Parity bit L2 No parity L3 Even parity L4 Odd parity Stop bit L5 1 stop bit L6 2 stop bits Handshaking Flow Control 5 3 4 The communication control method can be set using these commands Z2 save command in non volatile memory needs be use...

Page 57: ... so ready to receive data except during the processing of received data while transmitting data and while it is busy processing 1D 2D menu codes When the scanner wants to send data it first will check if its CTS line is on to be sure that the host is ready to receive data If the CTS line is off the scanner does not send the data but waits for a specific timeout period for the CTS line to be tuned ...

Page 58: ...ut I0 Flow Control timeout Indefinitely Enabled only with Z2 I1 Flow Control timeout 100 ms I2 Flow Control timeout 200 ms I3 Flow Control timeout 400 ms C MODEM The scanner s RTS is OFF as soon as power is supplied to the scanner The scanner will turn RTS ON when it wants to transmit data to the host The host should respond with CTS ON when it is ready to receive data While the host CTS is ON the...

Page 59: ... 0x11 The scanner terminates transmission without the good read or error buzzer Timeout If there is no response within 1 second the scanner terminates transmission with the error buzzer ACK NAK Flow chart BUZERn RxD TxD Scanner Host System RxD TxD Decode Finish Send ACK Wait Buzzer ACK LabelA LabelB LabelB Read Processing Start of transmission Transmit data Start 1 sec timer As configured Response...

Page 60: ... has been received correctly by the host Response ACK ASCII 0x06 The scanner terminates transmission with the good read buzzer Response NAK ASCII 0x15 The scanner sends the data again Response DC1 ASCII 0x11 The scanner terminates transmission without a good read or error buzzer Timeout If there is no response within 100 ms then the scanner terminates transmission with the good read buzzer ACK NAK...

Page 61: ...Following are the several countermeasures for the trouble caused by RS 232C Behavior Check points Countermeasures Cannot communicate No response when sending command Confirm communication settings 5 3 2 transfer speed 5 3 3 character format etc After changing communication setting send Z2 command Most of communication settings are not reflected until Z2 command is sent Confirm 5 3 4 handshake sett...

Page 62: ...ns such as barcode scanning while outputting decoded data However the reading performance may degrade during the data output When buffer mode is disabled the scanner stops other operations until the completion of decoded data output The following menu codes commands are provided for the data buffer mode setting Item Command Description Default Data buffer mode D80 Data buffer disable D81 Data buff...

Page 63: ...pecific options and number of characters to be read It is strongly recommended to enable only the required codes and options for best reading performance These settings do not affect the reading of the 1D menu codes Refer 9 3 Sample codes for the codes 6 1 Setting of Readable Codes 6 2 Setting of Code Common Options 6 3 Setting of Code Specific Option 6 4 Setting of Number of Characters ...

Page 64: ...ologies Enable Disable command Default Single Multiple Disable Enable Mini length Positive Negative Image ST SP trans mission CD check Suffix UPC J1 R1 X4B Positive Image Only USB HID ENTER USB COM RS 232C CR UPC A J1A R1A V1A UPC E J1B R1B V1B EAN JAN J4 R4 X4E EAN JAN 13 JG JU DDM EAN JAN 8 JA JO DDN Code 39 A2 B2 VB 1 Tri Optic JD JZ DDJ Codabar A3 B3 VC 2 Industrial 2 of 5 J7 R7 X4K 5 Interlea...

Page 65: ... Suffix Chinese Post Matrix 2 of 5 JE JS JT USB HID ENTER USB COM RS 232C CR Korean Postal Authority JL WH WI Intelligent Mail Barcode D5H D5F D5G POSTNET D6C D6A D6B PLANET DG2 DG3 DG4 Japan Postal D5R D5P D5Q Netherland KIX Code D5M D5K D5L Australian Postal D6O D6M D6N UK Postal Royal mail DG7 DG8 DG9 4 State Mailmark Barcode DGS DGT DGU ...

Page 66: ...panded GS1 DataBar Expanded Stacked JK DR SL Refer to 6 2 1 for convert GS1 and read GS1 Composite Code 6 1 4 Symbologies Enable Disable command Default Multiple Disable Enable Suffix Composite GS1 DataBar CC A CC B Limited CC A Limited CC B Expanded CC A Expanded CC B BHE BHF USB HID ENTER USB COM RS 232C CR Composite GS1 128 CC A CC B CC C Composite EAN EAN 13 CC A EAN 13 CC B EAN 8 CC A EAN 8 C...

Page 67: ...nes BF4 BF2 BF3 Chinese sensible code D4K D4L D4M Maxi Code BC2 BCE BCQ Refer to 6 2 1 for convert and read GS1 QR code and GS1 Data Matrix Other Options for Codes 6 1 6 Symbologies Single Multiple Disable Remark All codes 1D 2D A0 B0 Excluding add on All 1D codes BCA BCM BCY Excluding add on All 2D codes BCB BCN BCZ 1 2 1 PDF417 Codablock F QR Code Data Matrix ECC 200 Maxi Code MicroPDF417 Aztec ...

Page 68: ...TER USB COM RS 232C CR Machine readable Visa A DJ4 DJ5 DJ6 Machine readable Visa B DJ7 DJ8 DJ9 Official Travel Documents 1 DJA DJB DJC Official Travel Documents 2 DJD DJE DJF ICAO travel document can be read regardless of the image direction because the format is fixed OCR free edit To free edit standard OCR font and read refer to 6 2 7 OCR free edit For advanced setting please check the separate ...

Page 69: ...tted Initial setting status FNC1 Non output AI Data Fixed length AI Data Variable length FNC1 Non output AI AI Data Variable length GS1 after conversion For USB HID AIM ID output AI Data Fixed length AI Data Variable length Ctrl Key output AI AI Data Variable length For USB COM and RS 232C AIM ID output AI Data Fixed length AI Data Variable length GS 0x1D Output AI AI Data Variable length For AIM ...

Page 70: ...bar codes only Q1 Decode negative bar codes only Q2 Decode positive bar codes and negative bar codes It is strongly recommended to enable only the required codes and options for best reading performance Quiet Zone 1D code common 6 2 3 This option allows the scanner to decode barcodes that have smaller start and or end margins than standard for the symbologies Note that this option may increase the...

Page 71: ... 3 BS Read 5 time redundancy 4 BT Read 6 time redundancy 5 BU Read 7 time redundancy 6 BV Read 8 time redundancy 7 BW Read 9 time redundancy 8 This setting only affects the reading of 1D barcodes 2D codes are not affected by this redundancy setting Add on waiting time 6 2 5 The scanner search valid UPC EAN add on code within the selected time If effective add on code is found scanner sends data im...

Page 72: ...r following the back slack and 2 back lash indicates back slash To not to output ECI protocol change the data career identifier to ID not using ECI protocol delete the 6 digits number following the back slash and replace the 2 back slashes to 1 back slash Supported Code QR Code Data Matrix Aztec Code Maxi Code Output example Output Q2 000001test test Not output Q1test test Back slash Setting comma...

Page 73: ...CR standard format set from UniversalConfig OCR free edit function Numerical value alphabet symbol of up to 40 digits and 2 rows can be set For advanced setting please check the separate sheet Data Edit Programing Manual Please contact to the sales offices for the items cannot set ...

Page 74: ...PC A Add on 2 digits 5 digits UPC A add on 2 digits 5 digits is a barcode of UPC A plus 2 digits or 5 digits supplement code When Add on is enabled 2D scanner needs Add on code to be within the read range or fails to read If it is not within the range after Add on waiting time it reads as UPC or EAN When Add on is enabled and reading only UPC EAN reading response will decrease Transfer data format...

Page 75: ... is a barcode of UPC E plus 2 digits or 5 digits supplement code Transfer data format UPC E Add on 2 digits Leading 0 Data 6 digits CD 1 digit Add on 2 digits Transfer data format UPC E Add on 5 digits Leading 0 Data 6 digits CD 1 digit Add on 5 digits UPC E CD transfer front 0 transfer This allows you to set whether or not to transmit CD check digit and a leading 0 The 8 digits transfer data form...

Page 76: ...ngle UPC Add on 2 R2 Enable UPC Add on 2 X4C Disable UPC Add on 2 Add on 5 digits J3 Enable single UPC Add on 5 R3 Enable UPC Add on 5 X4D Disable UPC Add on 5 UPC E UPC E Leading zero CD transmission E6 UPC E Leading zero transmit CD transfer digits 8 digits E7 UPC E No leading zero transmit CD transfer digits 7 digits E8 UPC E Leading zero not transmit CD transfer digits 7 digits E9 UPC E No lea...

Page 77: ...Setting items EAN JAN 13 Add on 2 digits 5 digits EAN JAN 13 Add on 2 digits 5 digits is the barcode of EAN JAN 13 plus 2 digits or 5 digits supplement code When Add on is enabled 2D scanner needs Add on code to be within the read range or fails to read If it is not within the range after Add on waiting time it reads as UPC or EAN When Add on is enabled and reading only UPC EAN reading response wi...

Page 78: ...onversion of EAN 13 9791230671184 converts it to 1230671188 and outputs it ISBN conversion of EAN 13 9780123782830 converts it to 012378283X and outputs it ISSN conversion When ISSN conversion is enabled it converts data with a leading 977 of EAN 13 ISSN conversion will re calculate CD by omitting leading 3 digits and outputs it in 8 digits ISMN conversion When ISMN conversion is enabled it conver...

Page 79: ... the barcode of EAN JAN 8 plus 2 digits or 5 digits supplement code When Add on is enabled 2D scanner needs Add on code to be within the read range or fails to read If it is not within the range after Add on waiting time it reads as UPC or EAN When Add on is permitted and reading only UPC EAN reading response will decrease Transfer data format EAN JAN 8 Add on 2digits Data 7 digits CD 1 digit Add ...

Page 80: ...414 419 977 978 Enable EAN forced add on D When EAN 13 start at 434 439 414 419 977 978 Disable EAN forced add on ISBN Conversion IB Disable ISBN conversion IA Enable ISBN conversion IK When possible enable ISBN conversion ISSN Conversion HN Disable ISSN conversion HO Enable ISSN conversion 4V When possible enable ISSN conversion ISMN Conversion IO Disable ISMN conversion IP Enable ISMN conversion...

Page 81: ...n Settings Standard Code39 Send data character as it is Full ASCII Code39 This setting converts the correct combination of the data character to Full ASCII and transmits it If an incorrect combination is found in the character it will not be transmitted When possible Full ASCII Code39 This setting converts the specified combination of the data character to Full ASCII and transmits it Incorrect com...

Page 82: ...n D9 Transmit Code39 CD D8 Not transmit Code39 CD ST SP transmission D1 Not transmit ST SP D0 Transmit ST SP Full ASCII conversion D5 Normal Code 39 D4 Full ASCII Code 39 K Full ASCII Code 39 if possible It Pharm D6 It Pharmaceutical only D7 It Pharmaceutical if possible DA Not transmit leading A for It Pharm DB Transmit leading A for It Pharm Concatenation M Disable concatenation L Enable concate...

Page 83: ... ABC is an acronym of American Blood Commission It consists of 2 side by side barcodes Margin is necessary When the barcode s first stop character and the second start character is D it will be concatenated and sent Two D character will not be sent CX mode It consists of 2 side by side barcodes Margin is necessary When the barcode s first stop character is C and the second start character is B it ...

Page 84: ... Codabar CD ST SP transmission F0 Not transmit Start Stop code F1 Start Stop code ABCD TN E F2 Start Stop code abcd tn e F3 Start Stop code ABCD ABCD F4 Start Stop code abcd abcd HJ Start Stop code DC1 DC2 DC3 DC4 DC1 DC2 DC3 DC4 Space insertion HE Disable space insertion HD Enable space insertion ABC CX conversion HA Enable only Codabar normal mode H4 Enable only ABC code H5 Enable only CX code H...

Page 85: ...S Code and Matrix 2 of 5 CD check or not Interleaved 2 of 5 CD transmit Whether to transfer CD check digit or not is configurable This setting also configures Interleaved 2 of 5 Industrial 2 of 5 S Code and Matrix 2 of 5 CD transfer or not Industrial 2 of 5 space check Whether to enable disable the space inter character gap check of Industrial 2 of 5 which has large or irregular spaces can be set ...

Page 86: ...r setting detail Concatenation of Code 128 When Code128 data s leading is FNC2 character concatenate or not can be set Reading the barcode that contains FNC2 character in leading of Code128 data concatenate the data by omitting the leading FNC2 When reading the barcode that does not contains FNC2 character in leading of Code128 it concatenates the data to the end of data that is buffering to the s...

Page 87: ...0 4C Check 2 CD MOD 10 MOD 10 4D Check 2 CD MOD 10 MOD 11 4R Check 2 CD MOD 11 MOD 10 4S Check 2 CD MOD 11 MOD 11 CD transmission 4G Not transmit CD 4E Transmit CD 1 4F Transmit CD 1 and CD 2 UK Plessey 6 3 9 Code Item Command Description Default UK Plessey CD transmission 4O Not transmit CD 4N Transmit CD Space insertion DO Disable space insertion DN Enable space insertion X conversion DP Convers...

Page 88: ... Check 2CD BLI Check auto 1 or 2 CD CD transmission BLJ Not transmit CD BLK CD transmit Korean Postal Authority 6 3 12 Code Item Command Description Default Korean Postal Authority code CD transmission CD transmit Not transmit CD Transmit dash Transmit dash Not transmit dash Upside down reading 9 Upside down reading enabled 8 Upside down reading disabled ...

Page 89: ... numbers 20 types symbol function character FNC1 Digits GS1 DataBar Omnidirectional and GS1 DataBar Limited Application identifier 01 and 14 digits GS1 DataBar Expanded number 74 digits and alphabet 41 digits Check sum Check sum is always checked but not sent GS1 DataBar Omnidirectional Modulus 79 GS1 DataBar Limited Modulus 89 GS1 DataBar Expanded Modulus 211 CD check GS1 DataBar Omnidirectional ...

Page 90: ... is normal MicroPDF417 CC C is normal PDF417 Maximum digits CC A 56 character CC B 338 character CC C 2361 character Symbol size 1D part refer to GS1 DataBar and UPC EAN Composite part CC A and CC B are same as MicroPDF417 CC C is same as PDF417 Error correction 1D part error detection only Composite par Reed Solomon error correction Link flags GS1 DataBar and GS1 128 composite have link flags UPC...

Page 91: ... digits PDF417 Text compression 1850 character Byte compression 1108 character Numeric compression 2710 character Maximum digits MicroPDF417 Text compression 250 character Byte compression 150 character Numeric compression 366 character Symbol size PDF417 Number of lines 3 90 Number of rows 1 30 Symbol size MicroPDF417 Number of lines 4 44 Number of rows 1 4 Error correction PDF417 Error correctio...

Page 92: ...inese character Character specified by the shift coded expression of JIS X 0208 Maximum digits Alphanumeric data 4296 character 8 bit data 2953 character Numeric data 7089 character Chinese character data 1817 character Symbol size Minimum 21 x 21 module Maximum 177 x 177 module Error correction Reed Solomon error correction level 4 L 7 M 15 Q 25 H 30 Negative barcode mirror printing Negative and ...

Page 93: ...e shift coded expression of JIS X 0208 Maximum digits Alphanumeric data 21 character 8 bit data 15 character Numeric data 35 character Chinese character data 9 character Symbol size error correction Version M1 11 x 11 module Error detection only Version M2 13 x 13 module Reed Solomon error correction 2 steps L M Version M3 15 x 15 module Reed Solomon error correction 2 steps L M Version M4 17 x 17...

Page 94: ...ts ECC200 square Alphanumeric data 2335 characters 8 bit data 1556 characters Numeric data 3116 characters Maximum digits ECC200 rectangle Alphanumeric data 98 characters 8 bit data 47 characters Numeric data 72 characters Symbol size ECC200 Even rows and even columns square or rectangle Square minimum 10 x 10 maximum 144 x 144 module Rectangle minimum 8 x 18 maximum 16 x 48 module 6 patterns Erro...

Page 95: ...SCII value 0 127 ISO 646 ASCII value 128 255 ISO 8859 1 Alphabet No 1 Expand ASCII Using ECI many other character sets Maximum number of digits Alphanumeric data 3067 characters Number 3832 characters Byte 1914 character Symbol size Minimum 15 x 15 module Maximum 151 x 151 module Error correction The selectable error correction level is 5 to 95 of the data area Transfer data format Data variable l...

Page 96: ...ixed Length ON Minimum Maximum Length for Selected Codes 6 4 1 This option enables fixed length and minimum maximum length checking for each code types and will only affect the specified code types Configuration with commands Item Command Description Default valid range Fixed length Specify Code Input length of digits Fixed length for selected codes Length 1000a 100b 10c d 0 8000 6 4 2 Qa Qb Qc Qd...

Page 97: ...ar DC2 DB2 DA2 Industrial 2 of 5 DC3 DB3 DA3 Interleaved 2 of 5 DC4 DB4 DA4 Code 93 DCD DBD DAD Code 128 DCB DBB DAB MSI Plessey DC8 DB8 DA8 IATA DC7 DB7 DA7 PDF417 DCL DBL DAL QR code DCJ DBJ DAJ Data Matrix DCH DBH DAH Maxi code DCK DBK DAK Aztec code DCI DBI DAI MicroPDF417 DCM DBM DAM RSS Expanded GS1 Databar DCF DBF DAF Composite DCG DBG DAG GS1 128 DCC DBC DAC S Code DC5 DB5 DA5 UK Plessey D...

Page 98: ...ing Options L 46X User s Manual 88 1st 7 String Options This chapter describes the alterations which can be made to the transmitted data string The configurations available are 7 1 Case Conversion 7 2 Prefix Suffix ...

Page 99: ...host requires upper or lower case characters only Upper case Lower case conversion example Description AbCd Default No case conversion AbCd Convert to upper case ABCD Convert to lower case abcd Exchange case aBcD Upper case and Lower case can be set from following commands Items Command Description Default Case Conversion YZ No case conversion YW Convert to upper case YX Convert to lower case YY E...

Page 100: ...added in front of or at the end of the data for each specific symbology 1 By default the prefix is empty and the suffix of all codes is a CR character When using 6 2 7 OCR Free Edit or 8 4 4 Data Edit Reading this cannot be set Preamble Postamble up to 8 digits Specified characters can be added in front of or at the end of the data for all codes By default they are empty Preamble Prefix for each c...

Page 101: ...cation The code identification is transmitted in OPTICON ID ISO15424 standard or AIM ID Code length The code length is the number of characters after the output format that is configured with options in 6 3 Setting of Code Specific Options Scan time The scan time is the time from the trigger until the data output start ...

Page 102: ...ple to set C39 as the prefix and CR and LF as the suffix for Code 39 Command Esc M40CQ3Q96AO41M1J CR Prefix Suffix can also be set with 1D menu code or 2D menu code Note The prefix and suffix setting commands clear the current values and configure new ones The default suffix of CR is also cleared Clearing the default suffix CR is possible by scanning the RZ menu code Set suffix for all codes witho...

Page 103: ... prefix suffix setting command Code Prefix Command Suffix Command UPC A N1 N6 UPC A add on M0 O0 UPC E N2 N7 UPC E add on M1 O1 EAN 13 N3 N8 EAN 13 add on M2 O2 EAN 8 N4 N9 EAN 8 add on M3 O3 Code 39 M4 O4 Tri optic MC PN Codabar M5 O5 Industrial 2 of 5 M6 O6 Interleaved 2 of 5 M7 O7 S Code MB OB Matrix 2 of 5 GL GM Chinese Post Matrix 2 of 5 IATA I8 I9 MSI Plessey N0 N5 Telepen L8 L9 UK Plessey M...

Page 104: ...S1 DataBar Limited D6H D6K GS1 DataBar Expanded D6I D6L GS1 Composite code RR RS Codablock F D4S D4T Data Matrix MD PO Aztec BF0 BF1 Chinese Sensible Code D4N D4O QR Code MK PW Maxi Code ML PX PDF417 OC PY MicroPDF417 OD PZ Machine Readable Passports DJJ DJP Machine Readable Visas A DJK DJQ Machine Readable Visas B DJL DJR Official Travel Documents 1 DJM DJS Official Travel Documents 2 DJN DJT ISB...

Page 105: ... BEL 1G 5I I 0I i I H BS 1H 5J J 0J j J I HT 1I 5K K 0K k K J LF 1J 5L L 0L l L K VT 1K 5M M 0M m M L FF 1L 5N N 0N n N M CR 1M 5O O 0O o O N SO 1N 5P P 0P p P O SI 1O 6A Q 0Q q Q P DLE 1P 6B R 0R r R Q DC1 1Q 6C S 0S s S R DC2 1R 6D T 0T t T S DC3 1S 6E U 0U u U T DC4 1T 6F V 0V v V U NAK 1U 6G W 0W w W V SYN 1V 7A X 0X x X W ETB 1W 7B Y 0Y y Y X CAN 1X 7C Z 0Z z Z Y EM 1Y 7D 0 Q0 Z SUB 1Z _ 7E 1...

Page 106: ...ommand Esc RY 2 CR Code Length 7 2 5 For 1D codes the code length is transmitted as 2 digits excluding prefix and suffix characters For 2D codes the code length is transmitted as 6 digits It is also possible to send the length as 6 digits for both 1D and 2D codes These direct input characters count as 1 entry of the 4 permissible entries for a prefix and suffix Code length can be added by sending ...

Page 107: ...Chapter 8 Read Options L 46X User s Manual 97 1st 8 Read Options This chapter describes the read options for the scanner 8 1 Read Modes 8 2 Manual Trigger 8 3 Auto Trigger 8 4 Illumination and Aiming ...

Page 108: ... the same data The scanner starts reading after a trigger and stays reading even after a barcode is successfully decoded until the read time expires To prevent that a barcode is read twice the scanner saves the read barcodes in memory and checks if it has been read before The list in memory is 20 barcodes long so after 20 different barcodes the same barcode can be read again If there is more than ...

Page 109: ... the readout operation stops Item Command Description Default Remark Read time setting Y0 Using trigger key Auto trigger Synchronized with trigger key Auto Y1 1 second Y2 2 seconds Y3 3 seconds Y4 4 seconds Y5 5 seconds Y6 6 seconds Y7 7 seconds Y8 8 seconds Y9 9 seconds YM Read time infinite YL Read time 10 times When auto trigger with Y0 read time is automatically set by the image processing Whe...

Page 110: ...s shown below Item Command Description Default Central reading D00 Enable central reading read only a code at the center of aiming LED D0Z Disable central reading read within entire image Examples of readable positions in central reading setting Examples of unreadable positions in central reading setting When several codes are tightly packed it is recommended to use the Trigger Repeat See 8 2 1 fu...

Page 111: ...vior depends on the configuration of Read Time See 8 1 3 Item Command Description Default Trigger repeat K Disable trigger repeat M Enable trigger repeat The operation varies depend on the Read Cycle Timeout refer 8 1 2 Read time option When trigger key is synchronized Default Example While trigger is pressed Release trigger Output data Read time option When read time option is 1 second or more Ex...

Page 112: ...tation auto trigger Auto trigger Mode DL5 Presentation auto trigger mode DL6 Hand held auto trigger mode Auto Trigger Sensitivity 8 3 2 The detection sensitivity can be adjusted The sensitivity varies with the ambient environment and adjustment may be necessary Item Command Description Default Auto trigger sensitivity XMF Sensitive XMH Normal XMJ Insensitive Double read reset time 8 3 3 This allow...

Page 113: ...e 1000a 100b 10c d s 60 s 0 9999 Detection Mode 8 3 6 There are three methods for detecting a target code Warm white illumination detection When a target code falls within the range of the field of view of the warm white light the target is detected This mode is preferred in a dark environment Green aiming detection When a target code falls within the green aiming light the target is detected This...

Page 114: ...n in which a code was read is memorized and will be prioritized for subsequent reading This function is recommended when reading the target that specular reflection easily occurs LED Illumination Prevent specular reflection Disable illumination only when specular reflection by LED illumination occur and reads Item Command Description Default LED illumination mode D39 LED illumination Enable D3A LE...

Page 115: ...ere are items cannot be set with above Data Edit Function 8 4 4 Data edit script programming is a form of data output formatting so the user may change the scanned data to a format that is more desirable to be output This data edit script programming is integrated into the software of the scanner The Universal Config utility has some support for Data Editing but it is an advance language and may n...

Page 116: ...Chapter 9 Appendix L 46X User s Manual 106 1st 9 Appendix This chapter lists the reference data 9 1 Code ID Table 9 2 L 46X Specification Overview 9 3 Sample Codes ...

Page 117: ...t mail 0 EAN 8 A Postal TNT KIX 1 EAN 8 2 J Japan postal 2 EAN 8 5 K Postnet 3 Code 39 V Australia postal code 4 Code 39 Full ASCII W US Planet 6 Italian Pharmaceutical Y UK Postal Royal mail 7 Codabar R 4 state Mailmark barcode 8 Codabar ABC S Codablock F E Codabar CX f Data Matrix t Industrial 2 of 5 O Aztec o Interleaved 2 of 5 N Aztec Runes S Code g Chinese Sensible Code e Matrix 2 of 5 Q QR C...

Page 118: ...nt Mail Barcode X0 EAN 8 E4 POSTNET X0 EAN 8 2 E7 GS1 DataBar e0 EAN 8 5 E7 CC A e1 Code 39 A CC B e1 Code 39 Full ASCII A CC C e1 Tri Optic X0 GS1 DataBar with CC A e0 Code 39 lt Pharmaceutical X0 GS1 DataBar with CC B e0 Codabar F GS1 DataBar with CC C e0 Codabar ABC F Codablock F O Codabar CX X0 DataMatrix d Industrial 2 of 5 S0 Aztec z Interleaved 2 of 5 I X0 S Code X0 QR Code Q Matrix 2 of 5 ...

Page 119: ...transmit CD D8 A3 Full ASCII Code 39 D4 or Full ASCII Code 39 if pos K Check CD C0 Not transmit CD D8 A7 Codabar option AIM ISO15424 Code ID F Codabar normal mode HA Not check CD H7 Transmit CD H8 F0 Codabar normal mode HA Not check CD H7 Not transmit CD H9 F4 Codabar ABC H4 or H3 Not check CD H7 Transmit CD H8 F1 Codabar ABC H4 or H3 Not check CD H7 Not transmit CD H9 F5 Codabar normal mode HA Ch...

Page 120: ...10 MOD 10 4C 4C Transmit CD1 4E or 4C Not transmit CD 4G or 4C Transmit CD1 and CD2 4F X0 Check 2CD s MOD 11 MOD 10 4R 4D Transmit CD1 4E or 4D Not transmit CD 4G or 4D Transmit CD1 and CD2 4F X0 Telepen option AIM ISO15424 Code ID B Telepen numeric or ASCII only Telepen numeric followed by ASCII ASCII mode D3 B0 ASCII mode D3 B0 Numeric mode D2 B1 Numeric mode D2 B2 Telepen ASCII followed by nume...

Page 121: ...4 Structured append header included FNC1 preceding 1st message character ECI protocol implemented zA FNC1 following an initial letter or pair of digits ECI protocol implemented z5 Structured append header included FNC1 following an initial letter or pair of digits ECI protocol implemented zB Structured append header included z6 Structured append header included and FNC1 preceding 1st message chara...

Page 122: ...View angle Horizontal about 38 0 Vertical about 28 9 Diagonal about 46 4 Supported 1D Symbologies Symbologies 1D UPC A UPC E UPC E1 UPC A Add on UPC E Add on EAN 13 EAN 8 EAN 13 Add on EAN 8 Add on JAN 8 JAN 13 Code 39 Codabar Industrial 2 of 5 Interleaved 2 of 5 Code 93 Code 128 GS1 128 MSI Plessey Code 11 UK Plessey Telepen S Code Matrix 2 of 5 Postal Korean Postal Authority code Chinese Post Ma...

Page 123: ...lution mm PDF417 QR Code Data Matrix 0 169 mm 0 169 mm 0 169 mm PCS 0 9 Depth of field Typ PDF417 Resolution 0 169 8 105 mm Resolution 0 254 1 170 mm QR Code Resolution 0 169 19 70 mm Resolution 0 381 0 209 mm Data Matrix Resolution 0 169 21 75 mm Resolution 0 254 2 132 mm Common Scan angle Pitch 65 Skew 65 Tilt 360 Minimum PCS 0 2 or more MRD 13 or more OCR OCR font Machine Readable Travel Docume...

Page 124: ...torage 5 to 90 no condensing no frost Ambient light immunity Fluorescent 10 000 lx or less UPC 0 33 mm Sunlight 100 000 lx or less Vibration 10 Hz to 100 Hz acceleration of 19 6 m s 2 60 minutes per cycle repeat once in each X Y and Z direction Drop Drop 3 times at each 5 faces right left front back and top from a height of 180 cm onto a concrete surface Excluding the part where the interface cabl...

Page 125: ...reading depth of field Typical values of reading depth are as follows Resolution Code No of Digits or Character Scanning Depth of field mm Typ Near Far 0 127mm Code 39 4 digits 12 85 0 254mm Code 39 7 digits 11 196 0 508mm Code 39 4 digits 28 392 0 20mm Code 128 16 digits 9 150 0 33mm UPC EAN 12 digits 9 250 0 169mm PDF417 58 character 8 105 0 254mm PDF417 58 character 1 170 0 169mm QR Code 44 cha...

Page 126: ...d by tilting the test chart 15 from the optical axis 0 50 100 150 200 250 300 350 0 50 50 25 25 75 100 125 Unit mm 100 125 75 Code 39 Code 128 100 EAN UPC PDF417 QR Code Data Matrix 0 127mm 0 254mm 0 508mm 0 20mm 0 33mm 0 169mm 0 254mm 0 169mm 0 381mm 0 169mm 0 254mm 400 12 28 9 8 19 1 0 21 11 85 196 392 150 250 105 170 70 209 75 132 9 2 ...

Page 127: ...ield Typical values of reading depth are as follows Resolution Code No of Digits or Character Reading Depth of field mm Typ Near Far 0 076mm Code 39 5 digits 0 24 0 127mm Code 39 4 digits 0 41 0 254mm Code 39 7 digits 12 62 0 33mm UPC EAN 12 digits 13 digits 9 73 0 084mm QR Code 44 character 0 14 0 381mm QR Code 44 character 0 68 0 084mm Data Matrix 40 character 0 14 0 254mm Data Matrix 40 charact...

Page 128: ...ution UD model reading depth of field Unit mm 0 50 0 50 50 25 25 Code 39 UPC EAN QR Code Data Matrix 0 127mm 5mil 0 0 0 9 41 0 076mm 3mil 0 24 0 254mm 10mil 12 62 0 33mm 13mil 73 14 0 084mm 3 3mil 0 381mm 15mil 68 0 14 0 084mm 3 3mil 0 42 0 254mm 10mil 25 75 ...

Page 129: ...ter 9 Appendix L 46X User s Manual 119 1st Detailed View 9 2 3 Dimensions Approx 105 4 mm D 60 mm W 153 4 mm H except protruding portion Weight Approx 112 g excluding cable Mechanical Drawing 105 4 153 4 60 ...

Page 130: ...Chapter 9 Appendix L 46X User s Manual 120 1st Product Label 9 2 4 Example of label attached to the scanner is shown below 6 digit Serial Number prited here ...

Page 131: ...nnectors can be changed for to match local requirements Weight Approx 90 g Excluding AC plug for exchanging Mechanical Drawing as following drawing AC plug for exchanging DC output side The polarity of the center of DC jack is plus 1800 45 16 1 0 2 53 6 1 71 3 1 32 6 1 69 0 1 Unit mm 1 7 4 0 Unit mm EIAJ Electrode classification 2 EIAJ 2 ...

Page 132: ...Chapter 9 Appendix L 46X User s Manual 122 1st Sample Codes 9 3 1D Barcode 9 3 1 UPC UPC A UPC A 2 UPC A 5 UPC E UPC E 2 UPC E 5 ...

Page 133: ...Chapter 9 Appendix L 46X User s Manual 123 1st EAN JAN EAN JAN 13 EAN JAN 13 2 EAN JAN 13 5 EAN JAN 8 EAN JAN 8 2 EAN 8 5 ...

Page 134: ... 46X User s Manual 124 1st Code 39 Code 39 Code39 Italian Pharmaceutical Code 39 Full ASCII Tri Optic Codabar Codabar Codabar ABC Codabar CX Industrial 2 of 5 Interleaved 2 of 5 Industrial 2 of 5 Interleaved 2 of 5 S Code ...

Page 135: ...Chapter 9 Appendix L 46X User s Manual 125 1st Code 128 Code 93 IATA MSI Plessey IATA MSI Plessey UK Plessey Telepen UK Plessey Telepen Code11 Matrix 2 of 5 Code11 Matrix 2 of 5 ...

Page 136: ...User s Manual 126 1st Postal Code 9 3 2 Chinese Post Matrix 2 of 5 Korean Postal authority Intelligent Mail Barcode POSTNET PLANET Japan Postal Netherland KIX Code Australian Postal UK Postal Royal mail 4 State Mailmark Barcode ...

Page 137: ...L 46X User s Manual 127 1st GS1 DataBar 9 3 3 GS1 DataBar Omnidirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional GS1 DataBar Limited GS1 DataBar Expanded GS1 DataBar Expanded Stacked ...

Page 138: ...Chapter 9 Appendix L 46X User s Manual 128 1st GS1 Composite Code 9 3 4 CC A CC B Limited CC A Limited CC B Expanded CC A Expanded CC B Composite GS1 128 CC A CC B CC C ...

Page 139: ...Chapter 9 Appendix L 46X User s Manual 129 1st Composite EAN EAN 13 CC A EAN 13 CC B EAN 8 CC A EAN 8 CC B Composite UPC UPC A CC A UPC A CC B UPC E CC A UPC E CC B ...

Page 140: ...Chapter 9 Appendix L 46X User s Manual 130 1st 2D Code 9 3 5 PDF417 MicroPDF417 Codablock F QR Code Micro QR Data Matrix ECC 200 Aztec Code Aztec Runes Chinese sensible code Maxi Code ...

Page 141: ...Z L898902C 3JPN4209247M16092711234567890 78 Machine readable Visa A V UTOERIKSSON ANNA MARIA L8988901C4XXX4009078F96121096ZE184226B Machine readable Visa B V UTOERIKSSON ANNA MARIA L8988901C4XXX4009078F9612109 Official Travel Documents 1 I UTOD231458907 7408122F1204159UTO 6 ERIKSSON ANNA MARIA Official Travel Documents 2 I UTOERIKSSON ANNA MARIA D231458907UTO7408122F1204159 6 ...

Page 142: ...x L 46X User s Manual 132 1st OCR Font Free OCR Edit 9 3 7 OCR A OCR B OCR A Free Edit Enable OCR B Free Edit Enable 4567890 0123456789012 DEFGHIJ 23456CDEFGH 345678 89012345678 FGHIJKLMN 56789012ABCD Free Edit Disable ...

Page 143: ...Chapter 9 Appendix L 46X User s Manual 133 1st ...

Page 144: ......

Reviews: