Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner
Page 25
1. Global Default & Scanner Configurations
Computer
Command
Function
/Description
Bar Code
Command
(ZZ)
START/END Programming Menu
[[
U2
Return all parameters to
Default settings
V3
%
Z1
Transmit software version
[2
Z2
Save all values set by command
(not lost upon power off)
[3
Z3
Display software settings
including prefix/suffix
[!
Note: Where computer commands appear in parenthesis, bar code commands must be used to start and
end manual programming of the scanner.
Note: Scanner default settings are indicated by a pointing hand (
%
) symbol throughout the menus to
follow.
* Use Z2 (Save all values set by command) after computer command to store settings in memory prior to