Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner
Page 58
26. Positive & Negative Bar Codes
Computer
Command
Function
/Description
Bar Code
Command
(ZZ)
START/END
Programming Menu
[[
V2
Positive bar code only
(black bars/white spaces)
W3
%
V3
Negative bar codes
W!
V4
Both positive & negative bar
code
W5
27. Setting the Trigger & Auto-Trigger Functions
Computer
Command
Function
/Description
Bar Code
Command
(ZZ)
START/END
Programming Menu
[[
S7
Disable the trigger function
/ laser is ON continuously
T8
S8
Enable the trigger function /laser
is OFF until trigger is activated or
“pulled”
T9
%
+F
Disable Auto-trigger
,G
+I
Enable Auto-trigger
,J
%
Z
Activate the trigger; turns on the
laser
Use as
Computer Command
The Trigger function is enabled in the default setting. This means that the laser is “OFF” until triggered
by command or via the Auto-Trigger which is also enabled in the default setting. For some applications,
you may wish the laser to operate continuously, although this is not recommended. This can be done by
disabling the Trigger function using the S7 command. Once in the “Trigger Disabled” mode, the laser is
on continuously.
The software trigger is actuated by downloading and <ESC> Z <CR> computer command from the host.
(See Scanner Timeout to establish the length of time the scanning light remains ON after the trigger is
activated.) A hardware trigger is not available with this scanner.