Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner
Page 61
31. Scanner Timeout (Trigger Enabled Mode only)
These commands, which are only applicable in the Trigger Enabled mode, establish the time-out period
after the trigger pulse is received. In Single Read Mode, the time out is terminated upon a good read.
In Multiple Read and Continuous Read Modes the time out is reset after any good read.
Computer
Command
Function
/Description
Bar Code
Command
(ZZ)
START/END
Programming Menu
[[
Y1
1 Second after triggering
Z2
Y2
2 Seconds after triggering
Z3
%
Y3
3 Seconds after triggering
Z!
Y4
4 Seconds after triggering
Z5
Y5
5 Seconds after triggering
Z6
Y6
6 Seconds after triggering
Z7
Y7
7 Seconds after triggering
Z8
Y8
8 Seconds after triggering
Z9
Y9
9 Seconds after triggering
Z:
YL
Read time x 10
ZM
YM
Indefinitely after triggering
ZN