Manual No. 25-ULPNR102-01; Mar, 2005 LMD 1135 Laser Fixed Mount Scanner
Page 65
35. Transmitting Error Indications (Trigger Enabled only)
Computer
Command
Function
/Description
Bar Code
Command
(ZZ)
START/END
Programming Menu
[[
TH
Error message no label
UI
TI
Error message no decode
UJ
TG
Clear error messages for no label
and no decode
UH
WD
Disable response to command
XE
%
WC
Enable response to command
OK=ACK, ERROR=NAK
XD
WB
Buzzer Control to Command –
Disable
XC
WA
Buzzer Control to Command –
Enable
XB
%
Error Messages – No decode / no label
Messages may be user defined for the “no decode” and “no label” error modes independently.
Using the “Error message no label” (TH) and “Error message no decode” (TI) menu commands
a maximum of 4 characters may be user specified for transmission should these errors occur.
The following process should be followed to designate these error codes:
1. Scan “START” to enter the programming mode.
2
Scan “Error message no label” (TH).
3. Scan bar codes of the desired error message characters (4 max)
4. Scan “END” to end the programming sequence.
In a similar fashion, the “Error message no decode” (TI) can be defined.